background image

A-2

INSTALLATION   

MAGNUM X-TRACTOR 1GX

A-2

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have
thoroughly read all installation, operating  and  mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and  maintenance instructions.

ELECTRIC SHOCK can kill.

•Do not touch electrically live parts such

as internal  wiring.

•Insulate yourself from the work and

ground.

•Always wear dry insulating gloves.

------------------------------------------------------------------------

MOVING PARTS can injure.

•Do not operate with covers open or  fil-

ter removed.

•Keep away from moving parts.

------------------------------------------------------------------------

Only qualified personnel should install, use or  service
this equipment.

The Magnum X-Tractor 1GX vacuum source was
designed to provide the required fume extraction vacu-
um for any semiautomatic Magnum X-Tractor fume
extraction gun and cable assembly. The X-Tractor 1GX
will filter the collected visible particulate matter and
exhaust visibly clean air. There is an indicator light on
the unit that signals when the filter needs to be
changed. The 1GX uses a cardboard enclosed, dis-
posable filter that is extremely easy and clean to
change.

The 1GX vacuum is portable and is intended for light
duty or intermittent use. Because it has a disposable
(i.e. not cleanable) paper filter, the X-Tractor 1GX is not
recommended for heavy duty applications such as
Innershield®. The 1GX can be operated either in the
continuous mode or in the automatic mode. The auto
mode senses the current in the welding cable to turn
the vacuum on, and after a user determined time delay,
will turn itself off after welding stops.

GENERAL DESCRIPTION

The K173-2 Magnum X-Tractor vacuum source is
made up of a vacuum motor and control assembly, a
sheet metal filter cabinet with filter, and a metal spark
trap with an inlet pipe on it. These three basic compo-
nents fasten together and can easily be separated for
servicing. The vacuum is also shipped with a hose
adapter to fit 1-3/4” (45 mm) exhaust hose. Lincoln
Electric has 1-3/4” hoses for both regular duty (PVC
flexhose S19947- ) and heavy duty (Reinforced rubber
S14927-8) applications.

The vacuum motor and control are enclosed in a mold-
ed housing. Inside the housing are the vacuum motor
and blower. The motor uses a separate source of cool-
ing air, independent of the warm filtered air, to assure
cool operation. The motor also uses long life carbon
brushes that can be replaced should they ever wear
out. On top of the housing are the power on/off/auto
rocker switch, adjustable rotary knob to set the auto-
matic shut off delay time after welding stops, a full filter
indicator light to signal when the filter needs changing,
a pilot light to indicate that the power switch is in the
“auto” mode, and an area designed to accept the work
cable so the unit can sense welding current in the
cable.

The sheet metal filter cabinet is a non-pressurized cab-
inet. All the vacuum air flow passes through the totally
enclosed disposable filter and out the top of the cabi-
net through a sound trap. This means that the cabinet
can be drilled and mounted more permanently, as long
as the fasteners don’t puncture the cardboard filter
box. The filter can be removed from the cabinet with-
out tools, thrown away as a unit, and a new one
installed in one or two minutes.

Because the filter

media is totally enclosed, the user will not come in con-
tact with the collected matter.

The filter life varies

based on the electrode and welding parameters used.
The filter efficiency is 99.7%.

At the opposite end of the filter cabinet from the vacu-
um is the sheet metal spark trap and inlet pipe. The
spark trap can be removed without tools, emptied, and
replaced in about a minute.

Connection to Power Supply and
Welding Power Source

The Magnum X-Tractor 1GX vacuum source is shipped
from the factory with a standard grounded 115 volt plug
attached to the end of the 16.4 ft. (5 meter) long input
power cord. This plug can be mated to any 115V/50/60
Hz supply, either in the wall or the auxiliary receptacles
provided on some welding power sources.

WARNING

Содержание MAGNUM X-TRACTOR 1GX

Страница 1: ...M445 A February 1995 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overall safety can be increased by proper installation and t...

Страница 2: ...e welding the electrode electrode reel welding head nozzle or semiautomatic welding gun are also electrically hot 1 d Always be sure the work cable makes a good electrical connection with the metal be...

Страница 3: ...hem to prevent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near...

Страница 4: ...exhaust fumes outdoors ____________________________________________________ 7 c Do not add the fuel near an open flame welding arc or when the engine is run ning Stop the engine and allow it to cool b...

Страница 5: ...rans appropri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise...

Страница 6: ...e information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes...

Страница 7: ...2 Connection to the Gun and Cable Assembly A 3 Locating the Vacuum Source A 3 Operation Section B Safety Instructions B 1 Operating Instructions B 1 Maintenance Section C Safety Precautions C 1 Routi...

Страница 8: ...2 5 825 mm 34 lbs 15 5 kg FILTER LIFE Approximately 400 lbs of electrode under normal solid wire GMAW conditions PHYSICAL DIMENSIONS Air Flow without a hose Air Flow with provided hose attached 96 ft...

Страница 9: ...vacuum is also shipped with a hose adapter to fit 1 3 4 45 mm exhaust hose Lincoln Electric has 1 3 4 hoses for both regular duty PVC flexhose S19947 and heavy duty Reinforced rubber S14927 8 applicat...

Страница 10: ...odors it is recommended that the vacuum be placed away from the user and other personnel as far as convenient with in the constraints of the hoses and cables The filter cabinet of the 1GX is not press...

Страница 11: ...STRUCTIONS The 1GX vacuum can be operated in either the On or Auto mode by selecting the desired operation at the rocker switch on the motor housing In the On posi tion the vacuum will be on continuou...

Страница 12: ...ng of the spark trap over a waste bin until the trap is empty d Reinstall the trap and reconnect the hose Replacing the Filter The filter cartridge in the Magnum X Tractor 1GX is dis posable and shoul...

Страница 13: ...output problems Step 2 PERFORM EXTERNAL TESTS The second column labeled POSSIBLE AREAS OF MISADJUSTMENT S lists the obvious external possibilities that may con tribute to the machine symptom Perform...

Страница 14: ...ADJUSTMENTS S RECOMMENDED COURSE OF ACTION Low Vacuum Motor won t operate in any mode Motor won t operate in Auto mode 1 Be sure all tubing connections are tight and there are no punctures in hose 1 V...

Страница 15: ...RTS MAGNUM X TRACTOR 1GX 1 NOTE This Parts Manual is provided as an informative guide only when ordering parts always refer to the Lincoln Electric Parts List MAGNUM X TRACTOR 1GX PARTS MANUAL Code 10...

Страница 16: ...R 1GX 2 NOTE This Parts Manual is provided as an informative guide only when ordering parts always refer to the Lincoln Electric Parts List P 202 K MAGNUM X TRACTOR VACUUM SOURCE L8481 2 3 95K 7 8 9 1...

Страница 17: ...le S20000 3 1 4 Rubber Feet 3 pieces S20000 4 1 5 Handle S20000 5 1 6 Sound Trap S20000 6 1 7 Spark Trap S20000 7 1 8 Rocker Switch 3 Position S20000 8 1 9 Potentiometer S20000 9 1 10 Knob S20000 10 1...

Страница 18: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 19: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Отзывы: