![Lincoln Electric LINC FEED 34 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/lincoln-electric/linc-feed-34/linc-feed-34_operators-manual_1919128015.webp)
A-10
G. Configuration Menu
Description:
This hidden menu allows you to change the Machine Configuration.
To enter the set-up menu, press the
Select
pushbutton and at the same
time
Switch ON
the machine.
Knob 1:
Turn right or left
Knob 2:
Turn right or left
Choice of the configuration
Choice
Function
English
Spanish
Dutch
Italian
French
Swedish
•
LANGUAGE
German
Norwegian
Polish
Select the language you want to use.
•
ACCELERATION
From 1 to 3
Standard value: 2
Value used to determine the
acceleration of the wire between the
"Cold inch WFS" and the "Welding
WFS".
•
PRODUCT
TYPE
Not used
Shows Product Type:
•
"LF 37" for LF 34 Product.
•
"LF 38" for LF 35 Product.
•
SN
Not used
Shows Product Serial Number.
•
MAINTENANCE
YES / NO
Answer NO or contact Lincoln
representative.
•
CALIBRATION
YES / NO
Answer NO.
•
PROGRAM
LEVEL
Not used
Shows Program level of the Wire
Feeder.
•
RESET
YES / NO
If YES, you will:
•
Erase all the memories and their
status will become "empty".
•
Unlock the Recall memory mode if it
was locked.
•
Restore all the parameters to their
"DEFAULT" values.
•
EXIT
YES / NO
If YES, Press Select to Exit and save the
changes above.