* A minor modification is needed when K963 Hand Amptrol is used
with  the  V250-S.  The  braided  ground  strap  must  be  disconnected
from connector body on end of cable that attaches to the machine.
Remove cable clamp screw securing grounding strap, remove strap,
and reinstall screw. Run grounding strap along side of cable so that
it does not contact connector body, and secure in place with electri-
cal  tape.This  modification  is  necessary  in  order  to  avoid  coupling
electrical noise from the case of the machine onto the control leads,
which would otherwise result in poor starting and unstable welding
performance.

ATTACHING  THE  AMPTROL  TO  THE
TORCH.

Place  the  hand  Amptrol  along  the  TIG  welding  torch
cable,  as  shown  in  figure  1.    Slide  the  hand Amptrol
along  the  torch  handle,  so  the  control  knob  can  be
extended conveniently by the thumb.

CONNECTION OF THE AMPTROL TO THE
POWER SOURCE

With  power  source  off,  connect  6-pin  MS-type
(Amphenol)  connector  to  the  Remote  Receptacle  if
available,  or  use  required  adapter.    Secure  with  the
threaded collar*.  The Amptrol is designed for use with
a 25-ft TIG torch.  It is recommended that any excess
length be tucked under the power source.

Figure 1- Attaching the Amptrol to the Torch Handle

3

GROUNDING THE AMPTROL

Failure to properly ground the amptrol may cause
the unit to fail.

------------------------------------------------------------------------

If a K915-1 adapter is needed (when using a high freq
kit) or the equipment has a plastic amphenol, a ground
lead must be fastened from the cable clamp screw on
the hand Amptrol to the mounting screw on the amphe-
nol as shown in figure 2.

CAUTION

OPERATION

Extend the knob forward to start the welding sequence.
Extending the knob increases the current.  Extend the
knob fully to obtain the maximum set current. Retract
the knob to reduce the current. For equipment with out-
put  contactor  controls,  fully  retracting  the  knob  stops
the weld and stops the welding sequence. Refer to the 
power source and/or TIG accessories manual for spe-
cific operations instructions. 