PREPARING FOR USE

Before using Respirator – Check the Following Items

1.  Blower Assembly

•  Verify the air filter is proper for application and is NIOSH

approved for use with this respirator.  Verify the spark screen,
pre-filter and particulate filter are properly installed and
securely latched.

2.  Breathing Tube

•  Make sure tube is not damaged and connected properly to the

blower unit and helmet.

3.  Battery

•  Verify connection to blower unit is secure and that battery is

fully charged.

4.  Air Flow/Air Flow Alarms

•  Start blower unit and verify air flow rate is being maintained by

checking for air flow alarm activation.  Test to verify air flow
alarm is working (see page 15 for procedure).

5.  Helmet/Hood

•  Inspect helmet for damage and replace if necessary.  If air from

blower is not being supplied to helmet, see troubleshooting
guide (page 15).

VIKING PAPR FGS 3250D WELDING HELMET

Breathing
Tube

Check for 
Alarms

Blower 
Assembly

Battery

FIGURE 9

Содержание K4550-1

Страница 1: ...ate Purchased K ex K3930 1 Serial ex U1060512345 POWERED AIR PURIFYING RESPIRATOR PAPR WITH FGS 3250D AUTO DARKENING HELMET WARNING Users must read and understand the user instructions prior to use Us...

Страница 2: ...r Health IDLH Atmospheres are NOT oxygen deficient Contaminant concentrations do not exceed the Maximum Use Concentration MUC determined using the Assigned Protection Factor APF for specific respirato...

Страница 3: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 4: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 5: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 6: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 7: ...8 Shoulder Strap Installations 9 Respirator Controls 10 Air Flow Alarm Operation 11 Preparing For Use 12 Donning Procedure for Respirator 13 Respirator Maintenance and Storage 13 Trouble Shooting Guid...

Страница 8: ...manuals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators for use as surgical masks POWERED AIR PURIFYING RESPIRATOR SECTION RESPIRATOR SPECIFICATIONS S...

Страница 9: ...fore it becomes fully discharged Batteries not in use should be charged at least once a year Remove battery pack from blower assembly Connect charger cord to battery terminal Plug charger into 120 240...

Страница 10: ...that the battery pack snaps into position This makes sure the battery pack is locked in place and will not slide out causing possible nuisance shutoffs while in use To remove battery pack simply push...

Страница 11: ...figuration Install the spark screen pre filter and particulate filter in filter cover exactly as shown Install the filter cover assembly to the blower unit by engaging tabs on filter cover into bracke...

Страница 12: ...blower unit and the turn connector 1 8 of a turn clockwise to secure this end of breathing tube Connecting breathing tube to helmet Align pins of tube connector with channels in helmet receptacle Inse...

Страница 13: ...DER STRAP INSTALLATION Connect hooks 4 total on shoulder strap assembly to belt attachment points as shown VIKING PAPR FGS 3250D WELDING HELMET Shoulder Strap Assembly Hook Belt Attachment Location FI...

Страница 14: ...udible beeping sound indicates the OFF button has been depressed Beeping sound will stop and the user interface will darken when blower unit is off Battery Level Indicator This indicator gives the use...

Страница 15: ...work area immediately Do not remove the respirator until you are in a safe area Testing of Air Flow Alarm Testing of air flow alarm must always be done in a safe enviroment Disconnect breathing tube...

Страница 16: ...he blower unit and helmet 3 Battery Verify connection to blower unit is secure and that battery is fully charged 4 Air Flow Air Flow Alarms Start blower unit and verify air flow rate is being maintain...

Страница 17: ...the helmet and blower unit 1 Take off helmet and disconnect hose from helmet 2 Turn off blower unit by pressing OFF button 3 Release belt remove straps from shoulders and remove blower unit off of yo...

Страница 18: ...o enter downstream of blower 3 Filter 1 Inadequate charging 2 Clogged filter 3 Battery faulty 1 Filter is getting clogged 1 Press ON button 2 Charge battery 3 Verify battery pack is securely latched i...

Страница 19: ...n the arc stops Match your welding application to the shade indicated on the shade chart The lens must flip down before welding Do not use the auto darkening filter if damaged by shock vibration or pr...

Страница 20: ...lding Oxygen Cutting Grinding TIG Rating Operating Temperature Storage Temperature Compliance 1 1 1 1 1 with 4C Technology 74 106 mm 2 91 x 4 17in 4 DIN 4 DIN 4 5 to 8 9 to 13 Variable Shade Digital D...

Страница 21: ...T Tilt adjustment is located on the right side of the helmet Loosen the right headgear tension knob and push the top end of the adjustment lever inward until the lever s Stop Tab clears the notches Th...

Страница 22: ...applications Push FUNC button to adjust shade number sensitivity and delay settings before cutting In this mode the lens turns to dark immediately when you start cutting Grind Mode used for grinding...

Страница 23: ...de No 0 No 10 Grind Mode No sensitivity adjustment It may be necessary to adjust helmet sensitivity to accommodate different lighting conditions or if lens is flashing On and Off Adjust helmet sensiti...

Страница 24: ...s to adjust delay from 0 to 10 0 1 to 1 0 second When welding ceases the viewing window automatically changes from the darkened state back to light state but with a pre set delay to compensate for any...

Страница 25: ...e 7B and pull forward to remove ADF Figure 7C Replacing Outside Cover Lens Replace the front cover lens if it is damaged Remove Front Lens Holder per Figure 7A Remove Outside Cover Lens from the ADF a...

Страница 26: ...Make sure to assemble them into helmet shell the same way as it was removed FIGURE 10 Grind Shield Replacement Replace the Clear Grind Shield if it is damaged Remove Grind Shield Lens Holder per Figur...

Страница 27: ...de Window Cover Simply cover the Side Window with Side Window Cover make sure the covers are line up with the lens Installing Aftermarket Magnifying Lens Simply slide the magnifying lens into the shor...

Страница 28: ...djust your position so that the sensors can see the weld arc Make sure proper shade is selected Adjust sensitivity to required level Adjust delay time to required level Replace front cover lens as nee...

Страница 29: ...zing 3 or 4 Torch soldering 2 Carbon arc welding 14 PLATE THICKNESS in mm Gas welding Light Under 1 8 Under 3 2 4 or 5 Medium 1 8 to 1 2 3 2 to 12 7 5 or 6 Heavy Over 1 2 Over 12 7 6 or 8 Oxygen cutti...