English 21 English
Settings and Configuration Menu
To access the Settings and Configuration Menu:
Press the button [34] or right knob [33] to get access
to Welding Parameters Bar.
Use the right knob [33] to highlight the icon
“Configuration”.
Press the right knob [33] to confirm the selection.
Figure 37
Table 12 Configuration Menu
Symbol
Description
Limits
Display Configuration Settings
Brightness Level
Access control
Enable/ Disable Jobs Mode or Select
Jobs for Jobs Mode
Set the Language
Restore Factory Setting
Machine information
Advanced Setup
Cooler
Service Menu
Limits
– it allows the operator to set the limits
of main welding parameters in selected job.
The Operator is able to adjust the parameter
value within specified limits.
WARNING
Limits can be set only for the programs stored in the user
memory.
Limits can be set for below parameters:
Welding
Current
Wire Feed Speed
Welding
Voltage
Hot
Start
Arc
Force
Pinch
To set the range:
Enter to „Configuration” menu.
Use right knob [33] to highlight „Limits” icon.
Figure 38
Press right knob [33] to confirm. List with available
jobs will be shown on the screen.
Figure 39
Use right knob [33] to highlight the job.
Press right knob [33] to confirm selection.
Figure 40
Содержание K14186-1
Страница 44: ...English 42 English Connection configuration...