Lincoln Electric InvertecV350-PIPE Скачать руководство пользователя страница 2

FOR ENGINE
powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance

work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated

areas or vent the engine exhaust fumes
outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame

welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in

position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety

guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.

___________________________________________________

1.f. Do not put your hands near the engine fan.

Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.

i

SAFETY

i

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ‘95

ELECTRIC AND
MAGNETIC FIELDS
may be dangerous

2.a. Electric current flowing through any conductor causes

localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines

2.b. EMF fields may interfere with some pacemakers, and

welders having a pacemaker should consult their physician
before welding.

2.c. Exposure to EMF fields in welding may have other health

effects which are now not known.

2.d. All welders should use the following procedures in order to

minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and

work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as

possible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove the

radiator pressure cap when the engine is
hot.

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.

The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.

The Above For Diesel Engines

The Above For Gasoline Engines

Содержание InvertecV350-PIPE

Страница 1: ...um do lor sit am et co ns ec tet ue r ad ipi sc ing eli t ed dia m no nu mm y nib h eu ism od tin cid un t ut eli t ed dia m no nu mm y nib h eu ism od tin cid un t ut lao ree t do lor e ma gn a ali q...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...er for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both...

Страница 4: ...easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site sp...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan t...

Страница 6: ...mportant when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on the...

Страница 7: ...rocesses B 4 _______________________________________________________________________ Accessories Section C Options Accessories C 1 Factory and Advance Process Version C 1 Quick Disconnect Plugs C 1 __...

Страница 8: ...PIPE INPUT CURRENT OUTPUT CABLES CONNECTIONS AND LIMITATIONS Recommended Fuse Sizes Base On The U S National Electrical Code And Maximum Machine Outputs Input 50 60 Hz Output Recommended Note 1 Not r...

Страница 9: ...ng elit ed diam nonum my nibh euismo d tincidun t ut elit ed diam nonum my nibh euismo d tincidun t ut laoreet dolore magna aliquam erat laoreet dolore magna aliquam erat Lorem ipsum dolor sit amet co...

Страница 10: ...remote can be connected directly to the 6 pin MS style connector on the front of the Invertec or use a K864 adapter to connect the cobramatic and the remote to the 14 pin MS style connector LN 23P Co...

Страница 11: ...sired preset voltage value 5V Prior to STICK operation the meter displays the Open Circuit Voltage of the Power Source or four dashes if the output has not been turned on During welding this meter dis...

Страница 12: ...The maximum setting 10 will produce a crisp arc and will minimize electrode sticking CC STICK CRISP The Stick Crisp mode features continuous control from 60 to 250 amps This mode was intended primaril...

Страница 13: ...and ARC CONTROL features have different functions depending on the welding Mode that is active Each feature is described under the welding mode heading See Item 7 or 7 A for specified Mode Operations...

Страница 14: ...the 6 pin MS style connector pin D is positive AUXILIARY POWER 42 VAC and 24 VAC power is available from the 14 pin MS style connector These supplies are intend ed to supply power for auxiliary equipm...

Страница 15: ...10 K1587 1 Cobramatic V350 PIPE QUICK DISCONNECT PLUGS A quick disconnect system is used for the welding cable connections The K852 70 is designed to accept a welding cable size of 1 0 to 2 0 1 Remov...

Страница 16: ...removed Thermal Protection Thermostats protect the machine from excessive operating temperatures Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty...

Страница 17: ...CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause generally...

Страница 18: ...duty cycle is too high Reduce output current duty cycle or both 3 There is internal damage to the power source Contact an autho rized Lincoln Electric Service facil ity 1 Make certain that the power s...

Страница 19: ...r to wire feeder 1 Check for proper fan operation If fan is not operating correctly the CB 2 amp breaker may have opened Check for an overload on the 115VAC Blow air in rear lou vers to remove dirt fr...

Страница 20: ...h on the primary over Check the machine Self clearing as current fault interrupt possibly ground condition ceases caused by noise or a signal level If problem persists misc hardware fault 1 contact an...

Страница 21: ...initial three second period are displayed for 1 sec ond each Weld mode is changing A constant voltage weld mode is selected machine output is off The numeric value in the right display is the work po...

Страница 22: ...R A I G H T P L U G 1 4 P I N T O P O W E R S O U R C E C A B L E R E C E P T A C L E 6 S O C K E T C A B L E R E C E P T A C L E 1 4 S O C K E T T O 1 L N 7 W I R E F E E D E R S T O 1 K 8 5 7 R E M...

Страница 23: ...L C A B L E E F D A B C 7 7 7 6 7 5 S P A R E 4 2 2 1 8 2 8 1 4 2 4 1 G N D 3 1 3 2 N D N D R E M O V E 6 P I N P L U G F R O M K 4 3 2 C A B L E I N O R D E R T O C O N N E C T K 8 6 7 P L U G L A B...

Страница 24: ...5 5 A M P 1 1 5 V A C 2 A M P I N V E R T E C F R A M E C O N N E C T I O N N D N D F O R W I R E F E E D E R S T H A T R E T U R N A S I G N A L F O R W E L D I N G O U T P U T U S E I S O L A T I O...

Страница 25: ...C Y C L E O F A P P L I C A T I O N N B D I A G R A M S H O W S E L E C T R O D E P O S I T I V E T O C H A N G E P O L A R I T Y T U R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K...

Страница 26: ...I T Y T U R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E E L E C T R O D E C A B L E T O L N 7 T O W O R K 1 4 P I N A M P H E N O L L N 7 C O N...

Страница 27: ...ay not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to t...

Страница 28: ...1 4 3202 3207 3212 3213 3216 3215 3204 3203 3206 3205 13 25 14 1 251 OR 6 5 12 11 4 3 2 10 9 8 7 1 1 1 2 2 3 3 4 4 5 6 407 J61 J10B J10A J8 J9 J7 J6 J1 J331 J5 J4 J3 J332 J333 54 14 MODE ADVANCED PROC...

Страница 29: ...N PRINT F 8 V350 PIPE M19527 6 01 14 79 12 44 3 44 21 06 27 82 5 50 10 00 MOUNTING HOLE LOCATIONS 13 10 1 4 20 NUT 4 PLACES NOTE MOUNTING SCREWS CANNOT PROTRUDE MORE THAN 0 5 INCHES INSIDE THE MACHINE...

Страница 30: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 31: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 32: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...