Lincoln Electric INVERTEC V311-T AC/DC Скачать руководство пользователя страница 4

iii

SAFETY

iii

FOR ELECTRICALLY
powered equipment.

8.a. Turn off input power using the disconnect

switch at the fuse box before working on
the equipment.

8.b. Install equipment in accordance with the U.S. National

Electrical Code, all local codes and the manufacturer’s
recommendations.

8.c. Ground the equipment in accordance with the U.S. National

Electrical Code and the manufacturer’s recommendations.

CYLINDER may explode
if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely

chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

• Away from areas where they may be struck or subjected to

physical damage.

• A safe distance from arc welding or cutting operations and

any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other

electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet

when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand

tight except when the cylinder is in use or connected for
use.

7.g. Read and follow the instructions on compressed gas

cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.

WELDING and CUTTING
SPARKS can
cause fire or explosion.

6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to prevent

the welding sparks from starting a fire.

Remember that welding sparks and hot

materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,

special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.

6.c. When not welding, make certain no part of the electrode

circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the

proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even though they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society

(see address above).

6.e. Vent hollow castings or containers before heating, cutting or

welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil

free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.

6.g. Connect the work cable to the work as close to the welding

area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.

6.h. Also see item 1.c.

6.I. Read and follow NFPA 51B “ Standard for Fire Prevention

During Welding, Cutting and Other Hot Work”, available
from NFPA

1 Batterymarch Park, PO box 9101, Quincy, Ma

022690-9101.

6.j. Do not use a welding power source for pipe thawing.

Refer to 

http://www.lincolnelectric.com/safety

for additional safety information.

Содержание INVERTEC V311-T AC/DC

Страница 1: ...fety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overall safety can be increased by proper installation and thoughtful operation on...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...r cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welde...

Страница 4: ...to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...ponsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer In some cases this remedial action may be as simple as earthing grounding th...

Страница 7: ...ommendations Welding Cables The welding cables should be kept as short as possible and should be positioned close together running at or close to floor level Equipotential Bonding Bonding of all metal...

Страница 8: ...ly important when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on...

Страница 9: ...LCD Display B 4 B 5 B 6 Welding Parameter B 7 User Menu Set Up Parameters B 8 Set Up Menu Parameters Optional Cool Arc 35 Water Cooler B 9 B 10 Tips For Improved TIG Starting Stick Crisp Mode Dynamic...

Страница 10: ...18 0V 100 TIG 220A 18 8V 60 310A 22 4V 25 190A 27 6V 100 STICK 210A 28 4V 60 270A 30 8V 30 200A 18 0V 100 TIG 220A 18 8V 60 310A 22 4V 25 190A 27 6V 100 STICK 210A 28 4V 60 270A 30 8V 30 Maximum Open...

Страница 11: ...ts and cracks that allow high frequency leakage Cables with high natural rub ber content such as Lincoln Stable Arc better resist high frequency leakage than neoprene and other synthetic rubber insula...

Страница 12: ...n procedures can cause radio or TV interference prob lems RECONNECT PROCEDURE The Invertec V311 T AC DC auto reconnects to 208V 230V or 460V supply Fuse the input circuit with time delay fuses or dela...

Страница 13: ...t plugs must comply with the Standard for Attachment Plugs and Receptacles UL498 The product is considered acceptable for use only when an attachment plug as specified is properly attached to the supp...

Страница 14: ...for DC welding connect the electrode cable which is connected to the electrode holder to the output terminal and the work cable which is connected to the work clamp to the output termi nal Insert the...

Страница 15: ...ion 3 Slide rubber boot onto cable end The boot end may be trimmed to match the cable diameter Use soap or other nonpetroleum based lubricant to help slide the boot over the cable if needed 4 Insert c...

Страница 16: ...AC with square sinusoidal and triangular waveforms TIG DC with high frequency or Touch Start TIG Starting Stick DC Stick AC WELDING CAPABILITY The Invertec V311 T AC DC is rated at 310 amps 22 4 volt...

Страница 17: ...ower Switch is in the O Off position and therefore there are electrically live parts inside the power source Carefully follow the instructions given in this manual FIGURE B 1 1 Supply cable 2 Gas atta...

Страница 18: ...that output voltage is present above the limit Note The green VRD on light will illuminate in TIG mode until the output is triggered even when VRD is disabled Also note that enabling VRD to reduce th...

Страница 19: ...st selected parameter and begin the sequential scroll from that parameter Three Sequence Diagram types exist STICK See Figure B 4a TIG See Figure B 4b Pulse TIG See Figure B 4c 2 The Parameter Display...

Страница 20: ...pressing the arc start switch again causes the output to ramp down to the finish current level over the downslope time Finally releasing the arc start switch causes the arc to go out Refer to Figure B...

Страница 21: ...play will change to reversed text indicating that the current memory parameters are active Normal Display Reversed Display Unselected Selected Saving to Memory Press and hold Memory Save Button E unti...

Страница 22: ...tart Current Finish Current Min Current Upslope Downslope Spot Time Max Current Pulse Frequency Background Current Peak Time Postflow AC Frequency AC Balance Hot Start Arc Force Parameter Symbol unit...

Страница 23: ...ke background current shown in Figure B 7a the change is made by the mode push button In this example you can toggle between set ting background current as either a or as absolute amperage Other param...

Страница 24: ...gure B 7 Parameter Number 0 1 3 8 10 17 307 306 307 214 215 101 998 999 201 500 552 553 554 Description Set Up menu Exit Reset All Parameters Start Current Set Unit Bi Level Current 2 Set Unit Pulse B...

Страница 25: ...s designed to operate in communication with the Invertec V311 T AC DC Refer to the Cool Arc 35 operator manual for installation instructions and a complete description of its operation When the Invert...

Страница 26: ...thin the incremental range mode the machine tries to start electrode positive at a relative setting of 1 If the arc fails to establish it will repeat the start sequence each time by incrementing the a...

Страница 27: ...Invertec V311 T AC DC power source Features a tool storage tray for convenience and a cylinder platform to hold a gas bottle TIG TORCH STARTER KITS K2266 1 TIG Mate 17 Air Cooled TIG Torch Starter Pac...

Страница 28: ...ection for both gas and welding current K1622 4 Twist Mate adapter for Water Cooled TIG torches Adapter for PTW 18 and 20 Torches TIG Torch Parts Kits Parts kits are available for the TIG torches Thes...

Страница 29: ...a high voltage during power on condi tions This voltage is dangerous and must be dis charged before the machine can be serviced Discharging is done automatically by the machine each time the power is...

Страница 30: ...Lincoln Authorized Field Service Facility If you do not understand or are unable to perform the Recommended Course of Action safely contact your local Lincoln Authorized Field Service Facility HOW TO...

Страница 31: ...Inclusions Insufficient penetration Sticking Porosity Cracks 1 Long arc 2 High current 1 Fast movement of the electrode away from piece 1 Poor cleanliness or distribution of the Welding passes 2 Impr...

Страница 32: ...OF ACTION Oxidation Tungsten inclusions Porosity Hot cracking 1 lnsufficient gas 2 No protection on the back side 1 lncorrect electrode sharpening 2 Electrode too small 3 Operating failure contact of...

Страница 33: ...Voltage 2 Faulty supply plug or cable 3 Input voltage not within range 1 Incorrect setting up of the welding parameters 2 Low mains supply voltage 1 E01 E02 E03 DISPLAYED and the yellow control panel...

Страница 34: ...n it is necessary to remove the cause and exit the safety mode depressing the exit key button on the UI ALARM ID CODES E01 E02 E03 E10 E11 E19 E14 E15 E18 E17 E20 E21 E22 E27 E28 E29 E38 E39 E40 E43 E...

Страница 35: ...machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to the Service Department for...

Страница 36: ...d Entl ftung des Arbeitsplatzes G Mantenha seu rosto da fuma a G Use ventila o e exhaust o para remover fumo da zona respirat ria G Turn power off before servicing G Desconectar el cable de ali mentac...

Страница 37: ...parts or electrode with skin or wet clothing G Insulate yourself from work and ground G No toque las partes o los electrodos bajo carga con la piel o ropa moja da G Aislese del trabajo y de la tierra...

Страница 38: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: