Lincoln Electric INVERTEC V200-T Скачать руководство пользователя страница 14

B-2

OPERATION

B-2

INVERTEC V200-T

Power Switch/Voltage Selector Switch - Controls
the power input to the machine. This rotating switch is
used to turn the machine on and off as well as to
select the input voltage. The switch is located on the
top right rear panel. When power is applied to the
machine the Power LED is on.

Welding Current Potentiometer - Potentiometer
used to set the value of the current required by the
welding process. This current setting will be displayed
on the Digital Display.  When an Amptrol is used to
remotely control the welding current, this setting con-
trols the maximum welding current when the Amptrol
is fully depressed.

Voltage out of spec/ Overheated LED - This LED
will light up when:

A)  The input supply voltage is not within limits

pre-set for correct operation.*

B)  The machine is overheated as detected by

the internal thermostat.

* Note that input voltages that exceed 20% of nominal

may cause internal damage to the machine.

Output Terminals - These quick disconnect terminals
provide connection points for the TIG Torch and work
cables or electrode and work cables. For TIG welding,
connect the torch to the DC- terminal and the work
cable to the DC+ terminal. For stick welding positive
polarity connect the electrode cable to the positive ter-
minal and the work cable to the negative terminal. To
weld negative polarity reverse the electrode and work
cables.

Remote Control Connector - This receptacle will
accept a Lincoln Foot Amptrol, Hand Amptrol or Arc
Start Switch. See the ACCESSORIES section for
available options.

CONTROLS AND SETTINGS

All operator controls and adjustments are located on the case front of the V200-T machine. Refer to Figure B.1
and the corresponding explanations.

FIGURE B.1 — CASE FRONT CONTROLS.

Power LED

Gas Available LED

Digital Display

Voltage out of spec/
Overheated LED

Welding Current
Potentiometer

Slope Down
Time Pot.

Slope Up
Time Pot.

Post Flow
Time Pot.

Start/Crater
Current Pot.

Welding Process
Switch

Local/Remote
Switch

TIG Process
Switch

Pulse Duration
Potentiometer

Pulse Amplitude
Potentiometer

Pulse Frequency/
TIG Spot Timer
Potentiometer

DC- Terminal/
TIG Torch Terminal

Remote Control
Connector

DC+ Terminal

Содержание INVERTEC V200-T

Страница 1: ...on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful For us...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...ical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for co...

Страница 4: ...vent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan t...

Страница 6: ...e information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes...

Страница 7: ...B 1 Controls and Settings B 2 Operating Steps B 4 Welding in TIG Mode B 4 Remote Control Operation B 4 Welding in Stick Mode B 5 Recommended Electrode and Tungstens B 5 Explanation of 2 Step and 4 Ste...

Страница 8: ...nt Range 1 200 A INPUT SINGLE PHASE ONLY RATED OUTPUT OUTPUT RECOMMENDED INPUT WIRE AND FUSE SIZES Input Voltage phase Frequency 230 1 50 60 460 1 50 60 Input Ampere Rating on Nameplate 45 23 Type 75...

Страница 9: ...ubber coverings are free of cuts and cracks that allow high frequen cy leakage 4 Keep the torch in good repair and all connections tight to reduce high frequency leakage 5 The work piece must be conne...

Страница 10: ...may result in equipment damage The Invertec V200 T is internally connected for a 460 volt input The input switch has a lock pin which restricts movement for 460 selection only See figure A 1 To conne...

Страница 11: ...hese units to do TIG GTAW welding The Lincoln LA 9 K859 1 or K859 5 only with no gas valve or LA 17 and LA 17V K860 1 or K860 5 without gas valve and K860 9 or K860 13 with gas valve are recommended f...

Страница 12: ..._________________________ WARNING QUICK DISCONNECT PLUG FOR WORK CABLE A quick disconnect system is used for the welding cable connections The electrode and work cables need to have a plug attached 1...

Страница 13: ...FEATURES The Invertec provides continuous total range output current adjustment Additionally a hot start system has been built into the welding current control and provides a higher striking current t...

Страница 14: ...onnect terminals provide connection points for the TIG Torch and work cables or electrode and work cables For TIG welding connect the torch to the DC terminal and the work cable to the DC terminal For...

Страница 15: ...se within the selected pulse frequency see above Use this potentiometer to select the rela tive amount of peak and background current for the selected overall frequency Pulse Amplitude Potentiometer T...

Страница 16: ...is manual Both the Hand and Foot Amptrol work in a similar manner For simplicity the following explanation will refer only to Amptrols meaning both Foot and Hand models The term minimum refers to a fo...

Страница 17: ...32 Fleetweld 180 DC 40 80 55 110 105 135 Fleetweld 37 DC 70 95 100 135 145 Max Fleetweld 47 DC 75 95 100 145 135 Max Jet LH MR DC 85 110 110 160 130 Max Blue Max Stainless DC 40 80 75 110 95 110 Red...

Страница 18: ...e crater current set on the Start Crater Current Potentiometer The speed at which the welding cur rent decreases is determined by the setting of the Slope Down Time Potentiometer The power source come...

Страница 19: ...LA 17V 12 5 ft long back cup w gas valve K860 13 LA 17V 25 ft long back cup w gas valve NOTE Each torch requires a quick connector plug S22529 1 and strain relief boot M17255 be installed onto the cab...

Страница 20: ...let the input capacitors dis charge Failure to observe this discharge time requirement could result in severe electrical shock hazard 3 Keeping the machine clean will result in cooler operation and hi...

Страница 21: ...BLE CAUSE lists the obvious external possibili ties that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause genera...

Страница 22: ...ses open indicating excessive current draw 1 The input power switch must be in the ON position 2 Make sure the input voltage is correct for the machine 3 Check continuity of the 0 5 amp slow blow fuse...

Страница 23: ...achines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to the Service Department for a...

Страница 24: ...is provided as an informative guide only This information was accurate at the time of printing However since these pages are regularly updated in Lincoln Electric s official Parts Book BK 34 always ch...

Страница 25: ...numbers not listed Use the Illustration of Sub Assemblies page and the table below to determine which sub assembly page and col umn the desired part is located on for your particular code machine P 3...

Страница 26: ...11 4 98 INVERTEC V 200 T P 308 C P 308 C General Assembly...

Страница 27: ...astic Support S24105 24 1 X 25 Supply Cord S24105 25 1 X 26 Rear Gas Connector S24105 26 1 X 27 Supply Cord Strain Relief S24103 12 1 X 28 Aluminum Cover Red S24105 28 1 X 29 Rear Panel S24105 29 1 X...

Страница 28: ...INVERTEC V 200 T NOTES...

Страница 29: ...letin ED 80 or call 216 383 2259 and ask for the Welding School Registrar Lincoln Welding School BASIC COURSE 700 00 5 weeks of fundamentals There is a 10 discount on all orders of 50 00 or more for s...

Страница 30: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 31: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 32: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: