background image

B-6

OPERATION

B-6

Bi-Level Current –

(If Enabled from

the Setup Menu) Depressing an arc

start switch and releasing will initiate

the  arc  to  current  level  A1.

Depressing and releasing the arc

Start switch again will toggle to cur-

rent level A2. Each depressing and

releasing of the switch will toggle

between A1 and A2.  Depressing and

holding the switch in will initiate the

down slope to the finish current level

and finally releasing the trigger will

extinguish the arc.

Spot Timer -

(If Enabled from the

Setup Menu) Selecting this trigger

mode will enable a spot timer para-

meter setting to be displayed as a

welding parameter.  Once the arc is

establish the machine will weld for the

time period set by the spot timer para-

meter setting.  The machine will follow

the functionality of two-step in that

start current, up-slope, down-slope

and finish current can all be adjusted.

STICK TRIGGER MODES

Local -

In this mode the machine

ignores any remote that is plugged.

The machine will weld at the preset

value set at the panel of the machine.

Remote -

Allows the amperage to be

set with a remote potentiometer.

C. TIG PULSE MODES

Pulse On -

Turns on pulse welding in

TIG mode.  Changes the sequence

diagram to Pulse TIG and allows the

adjustment of the following added

parameters:

• Pulse Frequency

• % Peak Time

• Background Current

Pulse Off -

Turns off pulse welding in

TIG.

D, E, & F. Memory Operation –

Pressing and releas-

ing the memory location 

(D)

button will scroll through

memory locations 1 through 10.  When a memory is

recalled or saved the memory location display will

change to reversed text indicating that the current

memory parameters are active.

Normal Display         Reversed Display

(Unselected)

(Selected)

Saving to Memory

• Press and hold Memory Save Button 

(E)

until the

memory location display indicator 

(D)

changes to a

reverse text indicating that the current parameters

are the ones in the actively selected memory. 

Recalling from Memory

• Press and hold the memory recall button 

(F)

until

the memory location display indicator 

(D)

changes

to reversed text indicating that the stored parame-

ters are actively recalled. 

When memory parameters are actively selected,

the display indicator will remain reversed until a

welding parameter is changed with the encoder

knob or until the memory location button is pressed

to scroll to a different memory location

Local/Remote Operation –

The V310-T AC/DC,

when in TIG mode, will automatically sense when the

machine has a remote device plugged into the 6 pin

MS-type connector-like a remote pedant or a foot

amptrol.  If a remote device is plugged in, the machine

will automatically function in remote mode.  If no

device is plugged in, the machine will function in local

mode.

In remote mode, the operation of the machine is

slightly different depending on whether the remote

device is a foot amptrol or a remote pendant.  To let

the machine know what type of device is plugged in,

the operator must select the appropriate device from

the trigger mode button. (See Trigger mode descrip-

tions above for details on the difference.  In stick

mode the second button on the control panel selects

local or remote operation manually.  This is required

so that the user does not need to detach a foot amp-

trol to use the machine in STICK mode.

V310-T AC/DC TIG

 

 

 

 

 

 

 

Содержание INVERTEC IM958

Страница 1: ...ectric com World s Leader in Welding and Cutting Products Copyright Lincoln Global Inc Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...er for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both...

Страница 4: ...easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site sp...

Страница 5: ...appropri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paiss...

Страница 6: ...ation with the technical assistance of the manufacturer In some cases this remedial action may be as simple as earthing grounding the welding circuit see Note In other cases it could involve construct...

Страница 7: ...ng Cables The welding cables should be kept as short as possible and should be positioned close together running at or close to floor level Equipotential Bonding Bonding of all metallic components in...

Страница 8: ...pecially important when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the f...

Страница 9: ...ce Overview and Operation B 3 Dynamic LCD Display B 4 B 5 B 6 Welding Parameter B 7 User Menu Set Up Parameters B 8 Set Up Menu Parameters Optional Cool Arc 35 Water Cooler B 9 B 10 Tips For Improved...

Страница 10: ...18 0V 100 TIG 220A 18 8V 60 310A 22 4V 25 190A 27 6V 100 STICK 210A 28 4V 60 270A 30 8V 30 200A 18 0V 100 TIG 220A 18 8V 60 310A 22 4V 25 190A 27 6V 100 STICK 210A 28 4V 60 270A 30 8V 30 Maximum Open...

Страница 11: ...over ings are free of cuts and cracks that allow high frequency leakage Cables with high natural rub ber content such as Lincoln Stable Arc better resist high frequency leakage than neoprene and other...

Страница 12: ...cedures can cause radio or TV interference prob lems RECONNECT PROCEDURE The Invertec V310 T AC DC auto reconnects to 208V 230V or 460V supply Fuse the input circuit with time delay fuses or delay typ...

Страница 13: ...gs must comply with the Standard for Attachment Plugs and Receptacles UL498 The product is considered acceptable for use only when an attachment plug as specified is properly attached to the supply co...

Страница 14: ...C welding connect the electrode cable which is connected to the electrode holder to the output terminal and the work cable which is connected to the work clamp to the output termi nal Insert the conne...

Страница 15: ...ing cable insula tion 3 Slide rubber boot onto cable end The boot end may be trimmed to match the cable diameter Use soap or other nonpetroleum based lubricant to help slide the boot over the cable if...

Страница 16: ...at can per form the following types of welding with excellent results TIG AC with square sinusoidal and triangular waveforms TIG DC with high frequency or Touch Start TIG Starting Stick DC Stick AC WE...

Страница 17: ...l1 Power Switch is in the O Off position and therefore there are electrically live parts inside the power source Carefully follow the instructions given in this manual FIGURE B 1 1 Supply cable 2 Gas...

Страница 18: ...to show that output voltage is present above the limit Note The green VRD on light will illuminate in TIG mode until the output is triggered even when VRD is disabled Also note that enabling VRD to r...

Страница 19: ...e last selected parameter and begin the sequential scroll from that parameter Three Sequence Diagram types exist STICK See Figure B 4a TIG See Figure B 4b Pulse TIG See Figure B 4c 2 The Parameter Dis...

Страница 20: ...me Depressing the arc start switch again causes the output to ramp down to the finish current level over the downslope time Finally releasing the arc start switch causes the arc to go out Refer to Fig...

Страница 21: ...ation display will change to reversed text indicating that the current memory parameters are active Normal Display Reversed Display Unselected Selected Saving to Memory Press and hold Memory Save Butt...

Страница 22: ...ent Finish Current Min Current Upslope Downslope Spot Time Max Current Pulse Frequency Background Current Peak Time Postflow AC Frequency AC Balance Hot Start Arc Force Parameter Symbol unit Sec Amps...

Страница 23: ...ckground current shown in Figure B 7a the change is made by the mode push button In this example you can toggle between set ting background current as either a or as absolute amperage Other parameters...

Страница 24: ...B 7 Parameter Number 0 1 3 8 10 17 307 306 307 214 215 101 998 999 201 500 552 553 554 Description Set Up menu Exit Reset All Parameters Start Current Set Unit Bi Level Current 2 Set Unit Pulse Backgr...

Страница 25: ...Arc 35 water cooler is designed to operate in communication with the V310 T AC DC Refer to the Cool Arc 35 operator manual for installa tion instructions and a complete description of its operation W...

Страница 26: ...Incremental setting If start power is set within the incremental range mode the machine tries to start electrode positive at a relative setting of 1 If the arc fails to establish it will repeat the s...

Страница 27: ...H STARTER KITS K2266 1 TIG Mate 17 Air Cooled TIG Torch Starter Pack One complete easy to order kit pack aged in its own portable carrying case Includes PTA 17 torch parts kit Harris flowmeter regulat...

Страница 28: ...connection for both gas and welding current K1622 4 Twist Mate adapter for Water Cooled TIG torches Adapter for PTW 18 and 20 Torches TIG Torch Parts Kits Parts kits are available for the TIG torches...

Страница 29: ...gh voltage during power on condi tions This voltage is dangerous and must be dis charged before the machine can be serviced Discharging is done automatically by the machine each time the power is swit...

Страница 30: ...oln Authorized Field Service Facility If you do not understand or are unable to perform the Recommended Course of Action safely contact your local Lincoln Authorized Field Service Facility HOW TO USE...

Страница 31: ...lusions Insufficient penetration Sticking Porosity Cracks 1 Long arc 2 High current 1 Fast movement of the electrode away from piece 1 Poor cleanliness or distribution of the Welding passes 2 Improper...

Страница 32: ...CTION Oxidation Tungsten inclusions Porosity Hot cracking 1 lnsufficient gas 2 No protection on the back side 1 lncorrect electrode sharpening 2 Electrode too small 3 Operating failure contact of the...

Страница 33: ...supply plug or cable 3 Internal fuse blown 4 Input voltage not within range 1 Incorrect setting up of the welding parameters 2 Low mains supply voltage 1 E01 E02 E03 DISPLAYED and the yellow control...

Страница 34: ...ecessary to remove the cause and exit the safety mode depressing the exit key button on the UI ALARM ID CODES E01 E02 E03 E10 E11 E19 E14 E15 E18 E17 E20 E21 E22 E27 E28 E29 E38 E39 E40 E43 E44 E99 Te...

Страница 35: ...all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to the Service Department...

Страница 36: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 37: ...te Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentac...

Страница 38: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: