Setup menu 

The setup menu contains more parameters that are 
hidden from the main control panel functionality.   
 
To enter the Setup menu: 

Push and hold “SEL” and “MODE” pushbuttons 

 + 

 

 

Keep “SEL” + “MODE” pushed until the display shows 

” 

 

Then release the Pushbuttons 

 

 

now is shown the 

option number “00”

 

 

 

01 

 99 

 

Select the desired option: on the left display is shown 

the option number 

 

 

then press “SEL” to confirm 

 

 

 

 

Now enable, disable or change the option value: on the 

right display is shown the option status 

  

 

Save the desired option by pressing the “SEL” 

pushbutton 

 

 

To exit the setup menu select the 00 option and keep 

the SEL button pushed for 5 seconds until normal 

operation is resumed. 

 

 

List of menu options 

 Options 

Options 

Value 

00 Exit 

point 

-- 

01 2-step 

restart 

On/Off 

02 4-step 

restart 

On/Off 

10 Spot 

welding 

On/Off 

11  Spot fixed time 

On/Off 

20 Bi-Level 

On/Off 

30 Foot 

Pedal 

On/Off 

40  Arc start strenght 

1/2/3/4 

50*  Torch control function 

Off/Cur/Job 

51*  Limit max current 

Off/[Ampere] 

52*  Limit min current 

Off/[Ampere] 

99  Reset to factory default 

 

* valid only for 220TPX 
 
To change a setting push SEL, then rotate the encoder 
(Output Current Knob) to modify the setting, and push 
SEL again to confirm the new value. 
 

Error Codes and troubleshoting. 

If an error occurs, turn Off the machine, wait for a few 
seconds, then turn ON again.  If the error remains, a 
maintenance is required.  Please contact the nearest 
technical service center or Lincoln Electric and report the 
error code displayed on the meter of the Front Panel. 
 

Error code table 

01 

Input voltage too low 

 LED is blinking. 

Indicates that an Input Undervoltage protection 
is active; the Machine restarts automatically 
when the Input Voltage returns in the correct 
range. 

02 

Input voltage too high 

 LED is blinking. 

Indicates that an Input Voltage Overvoltage 
protection is active; the Machine restarts 
automatically when the Input Voltage returns in 
the correct range. 

03 

Wrong input connection 

 LED is blinking. 

Indicates that the machine is incorrectly wired. 
 
To restore the machine: 

  Turn OFF the machine and check the input 

connection. 

05 

DC bus short circuit 

 

 LEDs blink slowly together. 

Indicates that an Internal Power Circuitry fault 
condition is detected. 
 
To restore the machine: 
Turn OFF then ON the Mains Switch to restart 
the machine. 

Содержание INVERTEC 170TPX AUS

Страница 1: ...IM2050 10 2019 REV08 INVERTEC 170TX 170TPX 220TPX OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...e Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 170TX TPX CE model 1 Technical Specifications 17...

Страница 3: ...ne Duty Cycle 40 C based on a 10 min period Output Current I2 Output Voltage U2 230Vac 100 Stick 110A 24 4V 100 TIG 130A 15 2V 30 Stick 160A 26 4V 35 TIG 170A 16 8V OUTPUT RANGE Welding Current Range...

Страница 4: ...e 40 C based on a 10 min period Output Current I2 Output Voltage U2 230Vac 100 Stick 110A 24 4 V 100 TIG 130A 15 2 V 30 Stick 160A 26 4 V 30 TIG 170A 16 8 V 240Vac 15A circuit braker 100 Stick 75 A 23...

Страница 5: ...n a 10 min period Output Current I2 Output Voltage U2 230Vac 100 Stick 130 A 25 2 V 100 TIG 150 A 16 0 V 35 Stick 170 A 27 2 V 25 TIG 220 A 18 8 V 115Vac 100 Stick 90 A 23 6 V 100 TIG 110 A 14 4 V 35...

Страница 6: ...ne Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Persona...

Страница 7: ...in or adjacent to the work area and the machine Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equ...

Страница 8: ...or creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE Thi...

Страница 9: ...e part to touch a gas cylinder Gas cylinders must be located away from areas where they may be subjected to physical damage or the welding process including sparks and heat sources HF CAUTION The high...

Страница 10: ...e technical specification section of this manual Input Supply From Engine Driven Generators The machine is designed to operate on engine driven generators as long as the auxiliary can supply adequate...

Страница 11: ...enter Green Mode Green Mode Green Mode is a feature that puts the machine in a stand by condition The output is disabled The fan is turned OFF Only the Power ON LED remains ON A moving red dash is sh...

Страница 12: ...pslope Downslope ramps and Restart are disabled Spot Bi Level and 4 step functions aren t selectable Normal operation is restored when the Remote command is disconnected Thermal LED This indicator wil...

Страница 13: ...welding mode this command is disabled When Pulse is active is possible to set Duty cycle Frequency Hz and Background parameters During TIG welding is not possible switch ON or OFF the Pulse command i...

Страница 14: ...Voltage Press SEL Press SEL Wait 4s or start welding to store the changes Current Lift TIG GTAW welding To select Lift TIG welding Action Visualization Press MODE several times until the LED above lig...

Страница 15: ...final current value after the Downslope For an explanation of the Crater operation refer to the trigger sequences explained below 7 POSTFLOW In the TIG welding modes this function controls the shield...

Страница 16: ...ease the output current at a controlled rate or downslope time until the Crater current is reached and the output of the machine is turned OFF After the arc is turned OFF the gas valve will remain ope...

Страница 17: ...ch trigger is quickly pressed and released from step 3A it is possible to press and hold the TIG torch trigger another time to end the downslope time and maintain the output current at the Crater curr...

Страница 18: ...modes corresponding to different states of the machine are identified Before welding pressing the UP or DOWN key causes a change of value of the Set current While welding pressing the UP or DOWN key...

Страница 19: ...ult valid only for 220TPX To change a setting push SEL then rotate the encoder Output Current Knob to modify the setting and push SEL again to confirm the new value Error Codes and troubleshoting If a...

Страница 20: ...ected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufactur...

Страница 21: ...ue Hz Background ONLY 220 170 TPX 30 10 90 step 1 Current selected value of set current Downslope 0s 0 20s step 0 1s Current selected value s Crater 30 5 100 step 1 Current selected value of set curre...

Страница 22: ...r is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your...

Страница 23: ...alve Conn 35 50 K10513 9 z TIG torch LT 9 G 110A z 4m or 8m Ergo K10513 26 z TIG torch LT 26 G 180A z 4m or 8m Ergo K10529 26 z TIG torch LTP 26 G 180A z 4m 8m or 12m Ergo K10529 26 zX TIG torch LTP 2...

Отзывы: