Lincoln Electric INNERSHIELD PRO K126-10 Скачать руководство пользователя страница 12

A-5

INSTALLATION   

K126-10, K126-11 AND K126-12 INNERSHIELD® PRO

A-5

K466-4 Installation (For Hobart feeders; i.e. 27...)

1. Remove brass cable connector (see Figure A.2)

from the K466-4 kit and screw it on to the feeder
end  of  the  gun  cable.    Tighten  the  connector
with the wrench provided.

2. Attach the phone plug connector of the gun con-

trol  cable  provided  to  the  trigger  connector  on
the front of the Hobart feeder.

K466-5  Installation  (For  L-Tec  feeders  equipped
with  an  L-Tec  feeder  connector  assembly,  MIG
35, MIG 31A, 225...)

1. Remove brass cable connector (see Figure A.2)

from the K466-5 kit and screw it onto the feeder
end  of  the  gun  cable.  Tighten  the  connection
with the wrench provided.

2. For  L-Tec  machines  that  require  trigger  lead

connections to be made at a terminal strip locat-
ed  within  the  machine  (L-Tec  225),  a  gun  con-
trol  cable  with  forked  terminals  is  provided.
Connect  the  terminated  leads  to  the  terminal
strip.    For  a  machine  that  requires  a  twist-lock
gun  control  cable  connection,  continue  to  use
the L-Tec gun control cable provided with the L-
Tec  wire  feeder  connector  assembly.    Connect
the  twist-lock  plug  to  the  proper  receptacle  on
the machine.

K466-6,  K466-7,  and  K466-9  Installation
(Wirematic,  Hobart  Series  2000  Feeders,  SP100T
Type and Power MIG)

1. Remove  brass  cable  connector  (see  Figure  A.2)

from the connector kit and screw it onto the feeder
end of the gun cable.  Tighten the connection with
the wrench provided.

2. Attach the gun control cable provided to the trigger

connector on the wire feeder.

K613-2, K613-7 Installation  (Tweco #5 compatible
feeders)

1. Remove brass cable connector from the kit and

screw  it  onto  the  feeder  end  of  the  gun  cable.
Tighten  the  connection  with  the  wrench  provid-
ed.

2. For  K613-7,  attach  the  round  connector  of  the

gun  control  cable  provided  to  the  trigger  con-
nector on the front of the Lincoln feeder.

K613-6 Installation  (Lincoln Feeders, 3/32” diam-
eter wire)

1. Remove  brass  cable  connector  and  insulation

tube from the kit.  Slide the insulation tube onto
the connector from the threaded end and screw
it onto the feeder end of the gun cable.  Tighten
the connection with the wrench provided.

GUN HANDLE

CABLE

SHIELD CLAMPING SCREWS

GUN TUBE

TIP HOLDER

TIP

 INSULATOR

INSULATION TUBE

(K466-1 ONLY)

FEEDER END

CABLE HANDLE

BRASS CABLE

CONNECTOR

MOLDED GAS

PLUG

SET SCREW

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIGHT AGAINST BRASS CABLE CONNECTOR

GUN HANDLE

CABLE

SHIELD CLAMPING SCREWS

GUN TUBE

TIP HOLDER

TIP

 INSULATOR

INSULATION TUBE

(K466-1 ONLY)

FEEDER END

CABLE HANDLE

BRASS CABLE

CONNECTOR

MOLDED GAS

PLUG

SET SCREW

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIGHT AGAINST BRASS CABLE CONNECTOR

FIGURE A.2

Содержание INNERSHIELD PRO K126-10

Страница 1: ...tion on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READ ING THIS MANUAL AND THE SAFETY PRECAUTIONS CON TAINED THROUGHOUT And most importantly think before you act and be careful...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...r cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welde...

Страница 4: ...to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...time Lincoln Electric is not in a position to warrant or guarantee such advice and assumes no liability with respect to such infor mation or advice We expressly disclaim any warranty of any kind incl...

Страница 7: ...___________________________________________________________________ Accessories Section C Wire Feeder Connection Kits C 1 Gun Consumable Parts C 2 _____________________________________________________...

Страница 8: ...o 185 F 40C to 85C Cable Length 10ft 3 0m 15ft 4 5m Weight 7 3 lbs 3 3 kg 11 lbs 5 kg Electrode Diameter Range 035 3 32 0 8 2 4 mm Output Range Amperes 260A 100 duty cycle 350A 60 duty cycle Wire Feed...

Страница 9: ...X X X X X X X Trigger Lead Connector X X X X X X X X X Gas Tube and Fitting X X X Connector Tools X X X X X X X X X X Wire Feeder Connector Kits up to 5 64 diameter wire Note These kits must be used w...

Страница 10: ...KP2745 332R KP2908 1 KP2907 1 KP45H 322 15 KP2906 62 K613 3 15 ft 072 1 9 KP2745 072R K126 11 4 5 3 32 2 4 KP2745 332R KP2908 1 KP2907 1 KP45H 322 15 KP2906 62 K613 3 15 ft 072 1 9 KP2745 072R K126 1...

Страница 11: ...drive roll are appropriate for the electrode size being used On Lincoln feeders check that the K1500 2 gun adapter is in place 2 Fully push the brass connector end of the gun cable into the brass ada...

Страница 12: ...000 Feeders SP100T Type and Power MIG 1 Remove brass cable connector see Figure A 2 from the connector kit and screw it onto the feeder end of the gun cable Tighten the connection with the wrench prov...

Страница 13: ...he liner a 9 16 gage is included on the wrench supplied with the gun 7 Replace the gun tube and tighten the clamping screw to secure it 8 Reassemble the tip holder insulator and con tact tip onto the...

Страница 14: ...ck that the adapter and feeder outgoing guide as well as the drive rolls are appropriate for the electrode size being used 2 Fully push the brass connector end of the gun cable into the outgoing side...

Страница 15: ...nel should operate this equipment 1 Check that the welding power source is on 2 Position electrode over joint End of the electrode should be slightly off the work 3 Lower welding helmet close gun trig...

Страница 16: ...e none none K613 2 K613 3 K613 4 K613 5 none Model LN 7 LN 8 LN 9 series LN 25 0 052 max LN 742 LN 7 LN 8 LN 9 series LN 25 1 16 and larger LN 742 LF 72 LN 74 Series 10 feeders LN 15 PF 10M PF 15M Pow...

Страница 17: ...meter 0 035 0 045 0 052 1 16 0 068 0 072 5 64 3 32 10 piece pack KP2745 035R KP2745 045R KP2745 052R KP2745 116R KP2745 072R KP2745 072R KP2745 564R KP2745 332R 100 piece pack KP2745 035R B100 KP2745...

Страница 18: ...iner CABLE TIP HOLDER TIP INSULATOR FEEDER END CABLE HANDLE BRASS CABLE CONNECTOR SET SCREW LINER ASSEMBLY LINER BUSHING TO BE SEATED TIGHT AGAINST BRASS CABLE CONNECTOR LINER TRIM LENGTH 9 16 14 3 mm...

Страница 19: ...labeled POSSIBLE CAUSE lists the obvious external possibili ties that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possibl...

Страница 20: ...led 2 Machine s wire feed speed set ting is too low 3 Wire is obstructed somewhere along the wire feed path in the gun 4 Low motor voltage 5 Gun cable is coiled kinked 6 Mechanical resistance to wire...

Страница 21: ...echnique example ESO is too short 2 Wire may be feeding intermittent ly 1 Improper electrode polarity 2 Improper welding parameters or technique 1 Defective trigger contacts closed or dirty 2 Defectiv...

Страница 22: ...h electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 23: ...te Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentac...

Страница 24: ...NOTES K126 10 K126 11 AND K126 12 INNERSHIELD PRO...

Страница 25: ...NOTES K126 10 K126 11 AND K126 12 INNERSHIELD PRO...

Страница 26: ...NOTES K126 10 K126 11 AND K126 12 INNERSHIELD PRO...

Страница 27: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: