TROUBLESHOOTING & REPAIR
F-37
IDEALARC SP-250
Printed Circuit Boards can be dam-
aged by static electricity. Follow sta-
tic handling guidelines detailed in
“PC Board Troubleshooting
Procedures” at the beginning of this
chapter.
_____________________________
REMOVAL AND REPLACEMENT
PROCEDURE
MATERIALS NEEDED
5/16" Nut Driver
Phillips Head Screwdriver
Static Electricity Grounding Strap
1. Disconnect main input power the
machine.
2. Remove the Case Top and Side
Panels using 5/16" nut driver.
3. Disconnect all wiring harness
plugs and Molex Plugs connect-
ed to the Control Board. See
Figure F.11.
FIGURE F.11 - Wiring Harness and
Molex Plug Locations.
CONTROL PC BOARD REMOVAL AND REPLACEMENT