TROUBLESHOOTING & REPAIR
F-55
F-55
IDEALARC DC-655
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
FIGURE F.21 – OUTPUT CHOKE/MAIN TRANSFORMER ASSEMBLY DETAILS
CHOKE THERMOSTAT
(LEADS #273 AND 41A)
CHOKE / FRAME
MOUNTING
BOLTS (4)
ROPE SLING
TOP LEAD (#222A)
CENTER TAP
(LOW INDUCTANCE
OUTPUT LEAD)
BOTTOM CHOKE
LEAD (HIGH
INDUCTANCE
OUTPUT LEAD)
IRON/COIL
MOUNTING
BOLTS (4)
TRANSFORMER
SECONDARY
LEADS (6)
MAIN TRANSFORMER AND CHOKE REMOVAL
AND REPLACEMENT PROCEDURE
(continued)
PROCEDURE
1. Remove the input power to the DC-655
machine.
2.
Remove the case top and sides.
OUTPUT CHOKE REMOVAL
3.
Label and remove leads #273 and 41A from
the choke thermostat.
4.
Using the 9/16” wrench, remove the flexible
transformer secondary lead and the #222A
lead from the top lead of the output choke.
See Figure F.21.
5.
Using the 9/16” wrench, remove the low
inductance output lead from the center tap
of the choke. See Figure F.21.
6.
Using the 9/16” wrench, remove the high
inductance output lead from the bottom
choke lead. See Figure F.21.
7.
Support the choke with a crane or hoist.
8.
Using the 9/16” wrench, remove the four
bolts, washers and nuts mounting the choke
assembly to the transformer frame assem-
bly.
9.
Carefully lift the choke from the DC-655
machine.