Lincoln Electric IDEALARC AC/DC 250 Скачать руководство пользователя страница 6

6

v

v

Thank You

for selecting a 

QUALITY

product by Lincoln Electric. We want you

to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!

Read this Operators Manual completely

before attempting to use this equipment. Save this manual and keep it

handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:

WARNING

This statement appears where the information 

must

be followed 

exactly

to avoid 

serious personal injury

or 

loss of life

.

This statement appears where the information 

must

be followed to avoid 

minor personal injury

or 

damage to this equipment

.

CAUTION

Please Examine Carton and Equipment For Damage Immediately

When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.

Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.

Product _________________________________________________________________________________

Model  Number ___________________________________________________________________________

Code  Number or Date Code_________________________________________________________________

Serial  Number____________________________________________________________________________

Date  Purchased___________________________________________________________________________

Where  Purchased_________________________________________________________________________

Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.

On-Line Product Registration

- Register your machine with Lincoln Electric either via fax or over the Internet.

• For faxing:  Complete the form on the back of the warranty statement included in the literature packet

accompanying this machine and fax the form per the instructions printed on it.

• For On-Line Registration:  Go to our 

WEB SITE at www.lincolnelectric.com. 

Choose “Quick Links” and then

“Product Registration”. Please complete the form and submit your registration.

CUSTOMER ASSISTANCE POLICY

The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip-
ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses-
sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor-
mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.

Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.

Содержание IDEALARC AC/DC 250

Страница 1: ...incoln Global Inc All Rights Reserved For use with machines having Code Numbers 9491 9512 9513 9514 9548 9645 9646 9670 9712 9713 9738 9755 9992 9993 9994 9995 9996 9997 9998 11094 11100 11101 11102 1...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...er for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both...

Страница 4: ...easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site sp...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan t...

Страница 6: ...important when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on t...

Страница 7: ...8 TECHNICAL SPECIFICATIONS 9 INSTALLATION 10 11 Safety Precautions 10 Machine Installation 10 Location 10 Input Connections 10 Stacking 11 Installation of Field Installed Options 11 Output Cable Size...

Страница 8: ...ient voltages and high currents Submersion dipping of assembled transformer and choke in special sealing insulating material gives extra protection against moisture and corrosive atmosphere Stackabili...

Страница 9: ...Max O C V 72 70 72 70 Input Power Standard Voltages 208 230 460 220 380 440 230 460 575 380 415 500 Rated Input Current 230V 60Hz 220V 50Hz With Condensers 68 68 Without Condensers 86 86 Idle Input C...

Страница 10: ...Either a single phase or one phase of a three phase line can be used Have a qualified electrician install the machine per the following instructions Remove the left side panel viewed from the front R...

Страница 11: ...ated at the lower right and lower left corners of the front panel The 60 Hz Idealarc 250 provides 1 2 studs for weld cable connections The 50 Hz Idealarc 250 provides European weld cable connector rec...

Страница 12: ...esium thin stainless steel and many space age metals The Idealarc 250 can be used for normal stick electrode welding with the Hi Freq attached Reduce the Idealarc 250 duty cycle by 50 when AC TIG weld...

Страница 13: ...ls Note the ohmmeter reading using the 10 to 100 scale 4 Reverse the ohmmeter leads Note the readings 5 The reading taken in steps 3 and 4 should be different If the readings are the same and near zer...

Страница 14: ...ine switch in On posi tion Replace Look for reason for blown fuse first 2 Check supply line voltage 3 Repair 4 Check voltage against rating plate Check reconnect panel jumper 5 Tighten and repair conn...

Страница 15: ...4 Welding leads too small 5 Old and badly frayed welding cables 1 Line switch has failed mechanically 1 Contacts rough and pitted from improper switching under load WHAT TO DO 1 Check and clean all co...

Страница 16: ...E D S E C U R E L Y H 5 H 5 S E E T A B L E B E L O W F O R C O R R E C T C O N N E C T I O N 2 0 8 2 3 0 4 6 0 H 5 H 5 D O N O T T O U C H E L E C T R I C A L L Y H O T P A R T S S U C H A S O U T P...

Страница 17: ...T S I N P U T V O L T S 2 2 0 3 8 0 4 4 0 3 8 0 5 0 0 R E C O N N E C T P A N E L L E A D P O S I T I O N C O N N E C T I O N S M U S T B E T I G H T E N E D S E C U R E L Y H 5 H 5 H 5 H 5 D O N O T...

Страница 18: ...NOTES...

Страница 19: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 20: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 21: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...