TROUBLE SHOOTING
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized
Field Service Facility
for technical troubleshooting assistance before you proceed.
FLEXTEC™ 500
CAUTION
ERROR CODES
Errors are displayed on the user interface. In addition, there are status
lights on the User Interface PC board and the Switch PC board that
contain error sequences.
Included in this section is information about the status lights and
some basic troubleshooting charts for both machine and weld
performance.
The status lights on the User Interface board and the Switch board are
dual-color LED’s. Normal operation for each is steady green.
Error conditions are indicated in the following chart.
6
No CAN messages from Power Source
Communication from the Power Source failed before mapping was
compete.
Check the physical wiring connection of the CAN wires. Verify that the
switch board has input power from the auxiliary transformer.
18
ArcLink Auto-Mapping Failed
The machine could not properly configure the devices that are
attached to it. This configuration problem could be caused by the
type of devices that are connected to the machine or a required
device that is not connected.
Refer to the operators manual for proper configuration. Verify all
devices in the system are properly powered.
21
Device that controls sequence of the
welding operation halted due to an error
A component of the system encountered an error during the
welding sequence and caused the system to stop. The component
with the error could be a wire drive, a user interface or some other
part of the system.
Read the status LED of the switch board for a detailed fault code. Check
the event logs of the various system components to determine the
cause of the fault.
31
Primary Overcurrent
Peak current through the transformer primary has exceeded its
threshold.
Check the input power (voltage and frequency). Verify that the PC
boards an input rectifier are in working condition and proper input
power and welding output cable connections. Verify proper
connections of main internal power components. Power must be cycled
to the machine to reset the error.
36
Thermal Fault
Machine shutoff output due to elevated internal temperature.
Check for material blocking intake or exhaust louvers. Blow air in the
rear louvers to clear dirt from the fan. Note: (The Fan As Needed
circuitry automatically shuts off the fan 5 minutes after welding has
stopped). Welding output ratings may have been exceeded. Allow the
machine to cool down and reset. Measure the thermostats at the
Switchboard and replace if defective.
45
Output Voltage Limit Exceeded
During OCV, the voltage at the studs exceeded the allowable levels.
If VRD is enabled, the stud voltage exceeded 35 volts peak. In standard
operation, the stud voltage exceeded 113 volts peak. Verify the voltage
feedback leads are properly connected inside the machine. Verify the
input voltage is /- 10% of the nominal value.
213
Communication Fault
CAN communication between the User Interface PC board and the
Switch PC board has been interrupted.
Power must be cycled to the machine to reset the error. Visually
inspect the CAN harness to ensure connections and condition. Verify
power supply to the User Interface and Switch PC boards. Replace
defective assemblies as required.
711
DC Link Capacitor Over/Under Voltage
The voltage on the main DC link capacitors housed on the
swtichboard has either gone too high or too low.
Verify all three phases of the AC input line are connected properly to
the machine and that no fuses or breakers are damaged. Verify all
power connections to the main switch PC board.
713
Misconnect Protection - UI detected Aux.
Trans. Voltage too high
Occurs upon power up when the supply voltage to the User
Interface PC board exceeds an acceptable level.
Verify the primary reconnect is properly configured for the input
voltage
Power must be cycled to the machine to reset the error.
714
Misconnect Protection - UI detected Aux.
Trans. Voltage too low
Occurs upon power up when the supply voltage to the User
Interface PC board is below an acceptable level.
Verify the primary reconnect is properly configured for the input
voltage
Power must be cycled to the machine to reset the error.
719
Switch PC Board Error
The Switch PC board experienced an internal error.
Power must be cycled to the machine to reset the error. Replace the
switchboard if the error persists.
If any of these conditions persist contact an authorized Lincoln Field Service Shop.
Description
Corrective Action
Error Code
Содержание Flextec 500
Страница 8: ...8 CHANGES AFTER INITIAL RELEASE FLEXTEC 500 CHANGES AFTER INITIAL RELEASE...
Страница 12: ...12 NOTES FLEXTEC 500...
Страница 51: ...P 1067 C jpg Case Front Assembly Flextec 500 12606 5 Printed 09 29 2016 at 13 26 56 Produced by Enigma...
Страница 54: ...P 1067 D jpg Divider Panel Assembly 8 Flextec 500 12606 Printed 09 29 2016 at 13 26 56 Produced by Enigma...
Страница 57: ...P 1067 E jpg Base Center Assembly Flextec 500 12606 11 Printed 09 29 2016 at 13 26 56 Produced by Enigma...
Страница 59: ...P 1067 F jpg Case Back Assembly Flextec 500 12606 13 Printed 09 29 2016 at 13 26 56 Produced by Enigma...
Страница 61: ...P 1067 G jpg Wraparound Assembly Flextec 500 12606 15 Printed 09 29 2016 at 13 26 56 Produced by Enigma...