Lincoln Electric Demo Zone Скачать руководство пользователя страница 13

B-2

OPERATION

B-2

RECOMMENDED EQUIPMENT /
INTERFACE

EQUIPMENT LIMITATIONS

The Demo Zone is intended for indoor display and
demonstration use. The Demo Zone is intended for
light duty operation. Because of the input power limita-
tion, power sources (except Ranger 250) may only be
used at maximum output with low duty cycles. (Refer
to Welder Operation-Duty Cycle section of this manu-
al).

The Demo zone is not intended for road transportation
or to be hauled on a trailer. 

The Demo zone must not be lifted with gas cylinders
in place.

DESIGN FEATURES

PLATFORM COMMONALTIES

The Demo Zone utilizes standard power source and
wire feeder configurations. Output cables and torches
are modified in length for use with the Demo Zone. 

OPERATIONAL CONTROLS AND
FEATURES OF THE DEMO ZONE

Refer to the individual Operator’s Manuals for equip-
ment included in the Demo Zone.  

CIRCUIT BREAKER

The 230V input power to the Demo Zone is controlled
by a 40-amp circuit breaker located on the rear of the
Demo Zone.

REGULATORY REQUIREMENTS

The power source and wire feed equipment included
with the Demo Zone are individually listed or certified
to CSA or UL agencies. 

OPERATING INSTRUCTIONS

Read and understand the Operator’s Manuals for
all of the equipment contained in the Demo Zone.
The operating instructions for each equipment
type are not repeated here in the Demo Zone man-
ual.

Plug the Demo Zone into a 230 volt 40 amp recepta-
cle.  Locate the circuit breaker at the rear of the Demo
Zone and switch it on. Plug the lighting system into a
120 volt receptacle. Switch the power for individual
machines on as required for demonstration purposes.  

ADDITIONAL SAFETY PRECAUTIONS

WELDING AND CUTTING AREA

Welding and Cutting must take place only on the
welding table provided with the Demo Zone.  Do not
weld or cut on objects away from the Demo Zone
welding table.  Do not weld on the frame of the Demo
Zone. 

Direct sparks away from welding machines, especially
the fuel fill area of the Ranger 250.

POWER SOURCES

The Demo Zone is a flexible system capable of
demonstrating many varied processes.  The set-up of
equipment may require polarity changes, torch
changes or electrode changes.  Turn-off the welding
power source or plasma cutter when changing or con-
necting output cables torches or electrodes.  

DEMO ZONE

WARNING

CYLINDERS could explode 
if damaged.

•Keep cylinders upright and secured to

a support.

• Keep cylinders away from areas where they could

be damaged.

• Never allow the electrodes or torches to touch the

cylinders.

• Keep cylinders away from live electrical circuits.

• Maximum inlet pressures must be observed.

• Do not lift Demo Zone with gas cylinders in place.

• Do not strike an arc on any gas cylinders. Never

allow the electrode, electrode holder or any other
electrically "hot" parts to touch a cylinder.

• Gas cylinders must be securely fastened to the

Demo Zone frame. Chains are supplied and are
attached to the frame.

• When caster wheels are installed, block the

Demo Zone from movement when removing or
installing gas clinders.

WARNING

Содержание Demo Zone

Страница 1: ...INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful For use with equipment ha...

Страница 2: ...ERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of Safet...

Страница 3: ...arth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for cooling...

Страница 4: ...the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines...

Страница 5: ...t non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan talons...

Страница 6: ...to be applied to each is explained below WARNING This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life This statement appears where th...

Страница 7: ...ment B 1 Recommended Processes B 1 Process Limitations B 1 Recommended Equipment Interface B 2 Equipment Limitations B 2 Design Features B 2 Platform Commonalities B 2 Operational Controls and Feature...

Страница 8: ...67 lbs with gas cylinders 1346 2 mm 1676 4 mm 1346 2 mm 774 3 kg w o gas cylinders 1119 0 kg with gas cylinders The Demo Zone is intended for display and demonstration use It is intended for light dut...

Страница 9: ...high frequency unit of the Square Wave TIG 175 is used OUTPUT CABLES AND CONNECTIONS ELECTRODE AND WORK CABLE CON NECTIONS The Demo Zone is supplied with the output cables connected at the power sour...

Страница 10: ...gas cylinders are installed run the gun for the Power MIG from the back of the rack through the bench under and then up to the Power MIG This gun will run along the back of the Square Wave TIG 175 and...

Страница 11: ...flat surface The Demo Zone is intended for indoor use only The Demo Zone must be sheltered from rain and water ENGINE EXHAUST Provide an exhaust capability for the Ranger 250 machine Flexible metal ex...

Страница 12: ...ECOMMENDED PROCESSES The Demo Zone is capable of demonstrating MIG TIG SMAW CAC and plasma cutting PROCESS LIMITATIONS determined by individual equipment DEMO ZONE ELECTRIC SHOCK can kill Do not touch...

Страница 13: ...epta cle Locate the circuit breaker at the rear of the Demo Zone and switch it on Plug the lighting system into a 120 volt receptacle Switch the power for individual machines on as required for demons...

Страница 14: ...duty cycles of the Demo Zone are given If the duty cycle or input currents exceed the capability of the 40 amp circuit breaker the breaker will trip off For lower output currents the duty cycle is ext...

Страница 15: ...OPTIONS ACCESSORIES none FIELD INSTALLED OPTIONS ACCESSORIES CASTER WHEELS Caster wheels which are provided are a field installed option for the Demo Zone The 5 inch diame ter caster wheels offer hig...

Страница 16: ...or punctures in the cable jacket or any condition that would affect the proper opera tion Inspect gas hoses and regulators Inspect gas cylinder chains and fasteners The weld table is insulated from t...

Страница 17: ...performed by Lincoln Electric Factory Trained Personnel Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator For your safety and to avoid Elect...

Страница 18: ...OR GAS AND OIL RESISTANT 600 V UL B W 230 VOLT INPUT 50 AMP RECEPTACLE 50 AMP RECEPTACLE 50 AMP RECEPTACLE 50 AMP RECEPTACLE G TO GROUND PER NATIONAL ELECTRIC CODE N A BOX BONDED TO GROUND WORK CIRCUI...

Страница 19: ...NOTES DEMO ZONE...

Страница 20: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 21: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 22: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: