Lincoln Electric BESTER 210MP Скачать руководство пользователя страница 18

 

English 16 English 

WEEE 

07/06 

 

Spare Parts 

12/05 

  Part list reading instructions 

  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department 

for any code number not listed. 

  Use the illustration of assembly page and the table below to determine where the part is located for your particular 

code machine. 

  Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate a 

change in this printing). 

 
First, read the Part List reading instructions above then refer to the "Spare Part" manual supplied with the machine, which 
contains a picture-descriptive part number cross-reference). 
 
cross-reference). 
 

REACh 

11/19 

Communication in accordance with Article 33.1 of Regulation (EC) No 1907/2006 – REACh. 

Some parts inside this product contain: 
Bisphenol A, BPA, 

 

EC 201-245-8, CAS 80-05-7 

Cadmium, 

 

 

EC 231-152-8, CAS 7440-43-9 

Lead, 

 

 

 

EC 231-100-4, CAS 7439-92-1 

Phenol, 4-nonyl-, branched, 

EC 284-325-5, CAS 84852-15-3 

in more than 0,1% w/w in homogeneous material. These substances are included in the “Candidate List of Substances 
of Very High Concern for Authorisation” of REACh. 
Your particular product may contain one or more of the listed substances. 
Instructions for safe use: 

  use according to Manufacturer instructions, wash hands after use; 

  keep out of reach of children, do not put in mouth, 

  dispose in accordance with local regulations. 

 

Authorized Service Shops Location 

09/16 

  The purchaser must contact a Lincoln Authorized Service Facility (LASF) about any defect claimed under Lincoln's 

warranty period. 

  Contact your local Lincoln Sales Representative for assistance in locating a LASF or go to 

www.lincolnelectric.com/en-

gb/Support/Locator.

 

 

Electrical Schematic 

 
Refer to the "Spare Part" manual supplied with the machine. 
 

English

 

 

Do not dispose of electrical equipment together with normal waste! 
In observance of European Directive 2012/19/UE on Waste Electrical and Electronic Equipment (WEEE) 
and its implementation in accordance with national law, electrical equipment that has reached the end of 
its life must be collected separately and returned to an environmentally compatible recycling facility. As 
the owner of the equipment, you should get information on approved collection systems from our local 
representative. 
By applying this European Directive you will protect the environment and human health! 

Содержание BESTER 210MP

Страница 1: ...IM3148 11 2020 REV01 BESTER 210MP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o Jana III Sobieskiego 19A 58 260 Bielawa Poland ww lincolnelectric eu...

Страница 2: ...he table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Number Date Where Purchased ENGLISH INDEX Technic...

Страница 3: ...tage Range MIG U0 90V 30A 200A 15 5V 24 0V FCAW SS U0 90V 30A 200A 15 5V 24 0V MMA U0 90V 15A 180A 20 6V 27 2V TIG U0 90V 15A 180A 10 6V 17 2V OTHER PARAMETERS Power Factor Efficiency and idle power c...

Страница 4: ...des Welding time in seconds D16 16A slow blow 2 0 60 70 10 Continuous work D16 16A slow blow 2 5 85 90 10 Continuous work D16 16A slow blow 3 2 120 125 6 450 D16 16A slow blow 4 0 130 145 Half of elec...

Страница 5: ...G mode STICK mode After 30 minutes of non working Fan off The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1 2...

Страница 6: ...process gas usage depends on cross sectional area of the nozzle For comonnly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may...

Страница 7: ...ke pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may requi...

Страница 8: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Страница 9: ...lding process including sparks and heat sources CYLINDER can be fasten on the machine s shelf but the height of gas cylinder doesn t have to be higher than 1 1m The gas cylinder which is fastened on t...

Страница 10: ...s machine must be located where there is free circulation of clean air without restrictions for air movement to and from the air vents Do not cover the machine with paper cloth or rags when switched o...

Страница 11: ...down in order to prevent damage to welder Output Connections Refer to points 8 9 and 10 of the Figure 2 Power Source Placement and connections WARNING Avoid excessive dust acid and corrosive material...

Страница 12: ...lation and connection Figure 4 If the welding polarity has to be changed user should Switch off the machine Determine the polarity for the electrode to be used or wire Consult the data for this inform...

Страница 13: ...Turn the welding machine off Depending on welding process connect the proper gun to the euro socket the rated parameters of the gun and of the welding machine should be matched Remote the nozzle from...

Страница 14: ...o MIG 6 Figure 2 The welding machine is now ready to weld By applying the principle of occupational health and safety at welding welding can be begun Welding MIG FCAW SS Process in Manual Mode In BEST...

Страница 15: ...l will cause that the manufacturer s warranty will become null and void Any noticeable damage should be reported immediately and repaired Routine maintenance everyday Check condition of insulation and...

Страница 16: ...or any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such info...

Страница 17: ...nnected Check the connection 4 Arc is not stable and spatter is large Too large contact tip makes the current unsteady Change to proper contact tip and or drive roll Too thin power cable makes the pow...

Страница 18: ...Substances of Very High Concern for Authorisation of REACh Your particular product may contain one or more of the listed substances Instructions for safe use use according to Manufacturer instruction...

Страница 19: ...25 1 08R Adapter for spool S200 200mm K10158 1 Adapter for spool type B300 K10158 Adapter for spool type S300 W10529 17 4V TIG torch WTT2 17 4m with valve E H 200A 25 3M Welding cable with electrode h...

Отзывы: