Memory Selection:

 

 

 

 
The memory function is designed to allow the operator to 
save up to 9 specific welding procedures.  This memory 
button will have two functions: 
1.  Save memory settings 
2. Recall memory settings. 
 
Selecting Memory Functions:  Pressing the memory 
button will allow the user to toggle between “saving” a 
memory, “recalling” a memory or operating without using 
a memory setting. 
1.  Pushing 1 time “M” icon, SAVE icon turned on. 
2.  Pushing 2 times “M” icon, RECALL icon turned on. 
3.  Pushing 3 times Icon and diplays turn off. 
 
Saving Memory Settings: 
In order to save process settings into a memory location it 
is first necessary to press the memory button so that the 
“memory save” icon is highlighted.  Once highlighted, the 
number on the screen will flash to indicate this number 
can be changed by turning the control knob below, and 
the voltage and amperage meters will say “MEM SET”. 
Once the desired memory location has been selected 
using the control knob, pressing and holding the memory 
button for 3 seconds will save the settings in that location.  
During the 3 second hold period the “memory save” icon 
will flash.  After 3 seconds the displays will show “MEM 
SAVE” 
 
OPERATION: 
1.  Press Memory button to highlight “Memory Save” icon; 
2.  Turn Control Knob to Select memory location; 
3.  Press and hold memory button for 3 seconds. 
 
Recalling Memory Settings: 
In order to recall process settings it is first necessary to 
press the memory button so that the “memory recall” icon 
is highlighted.  Once highlighted, the number on the 
screen will flash to indicate this number can be changed 
by turning the control knob below, and the voltage and 
amperage meters will say “MEM RECL”. Once the desired 
memory location has been selected using the control 
knob, pressing and holding the memory button for 3 
seconds will recall the settings from that location.  During 
the 3 second hold period the “memory recall” icon will 
flash.  After 3 seconds the displays will show “RECL 
MEM” 
 
OPERATION: 
1.  Press Memory button to highlight “Memory Recall” 

icon. 

2.  Turn Control Knob to Select memory location. 
3.  Press and hold memory button for 3 seconds. 
 

Menu:

 

 

 

 
This unit permits an advance setting divided in 3 menu: 

1.  If process GTAW Press and Hold 

 for 5 seconds 

to access setup menu “GTAW”. 

2.  If process SMAW Press and Hold 

 for 5 seconds 

to access setup menu “SMAW”. 

3. In all process Press and Hold 

 + 

 for 

5 seconds to access setup menu “SYS”. 

4.  Upon entering one of the three menus , progression is 

accomplished by pressing 

5.  While moving backward is accomplished by pressing 

6.  Changes to menu items will be accomplished by using 

the Control Knob 

7.  After an item is changed it will be saved if 

 or 

 

is pressed. 

8.  Each menu can be exited by pressing 

 

Содержание ASPECT 200

Страница 1: ...IM3122 04 2020 REV01 ASPECT 200 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...cord in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDE...

Страница 3: ...0 115Vac 1ph STICK DC 100A 60A 45A 24V 22 4V 21 8V TIG DC 115A 90A 70A 14 6V 13 6V 12 8V STICK AC 100A 60A 45A 24V 22 4V 21 8V TIG AC 115A 90A 70A 14 6V 13 6V 12 8V Input Line Mode 30 35 60 100 30 35...

Страница 4: ...rator must check the work area for any devices that may malfunction because of electromagnetic disturbances Consider the following Input and output cables control cables and telephone cables that are...

Страница 5: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Страница 6: ...contact free ignition with TIG GTAW welding can interfere with the operation of insufficiently shielded computer equipment EDP centers and industrial robots even causing complete system breakdown TIG...

Страница 7: ...bility in this manual Do not operate in areas with an ambient temperature greater than 40 C Input Supply Connection Check the input voltage phase and frequency supplied to this machine before turning...

Страница 8: ...COOLARC 24 If a Coolarc unit listed above is connected to the Machine it will be automatically turned ON and OFF in order to ensure the torch cooling When Stick welding mode is used the cooler will b...

Страница 9: ...active the Power ON LED starts blinking and an error code is shown on the displays The machine restarts automatically when the Input Voltage returns in the correct range For further detail read the Er...

Страница 10: ...In menu SMAW is possible to change hot start and arc force diagram NOTE Pressing the button assigned to PROCESS selection will toggle the illumination of the icon from left to right following the pro...

Страница 11: ...ctions sets the amount of time the pulse waveform spends at the peak current setting This function is set as a percentage of the total time for the pulse cycle Pulses Per Second Sets the total number...

Страница 12: ...rol Knob to Select memory location 3 Press and hold memory button for 3 seconds Recalling Memory Settings In order to recall process settings it is first necessary to press the memory button so that t...

Страница 13: ...lding puddle That means Electrode workpiece sticking prevention also with low current values Spatters reduction The welding operations are simplified and the welded joins looks better also if not brus...

Страница 14: ...select 2 Step sequence Output Visualization Press several times until the LED above lights up With the 2 step trigger mode and a TIG welding mode selected the following welding sequence will occur 1 P...

Страница 15: ...p With the 4 step trigger mode and a TIG welding mode selected the following welding sequence will occur 1 Press and hold the TIG torch trigger to start the sequence The machine will open the gas valv...

Страница 16: ...and released from step 3A it is possible to press and hold the TIG torch trigger another time to end the downslope time and maintain the output current at the Crater current When the TIG torch trigger...

Страница 17: ...TIG torch trigger when the main part of the weld is complete The machine will now decrease the output current at a controlled rate or downslope time until the Crater current is reached This Crater cur...

Страница 18: ...ep 5 Note B PEAK of FREQ Pulses Per Second DC Only when pulse function is enabled 0 1 0 1 10 Hz step 0 1Hz 10 500Hz step 1Hz 500 2000Hz step 10Hz FREQ Current selected value Hz Pulses Per Second AC On...

Страница 19: ...uency the PEAK is fixed to 50 Note D Once AUTO is selected the default parameter are used Menu GTAW To enter into Menu GTAW see section Menu described above The ADVANCED menu part is available only in...

Страница 20: ...mm 0 04 1 6mm 1 16 2 4mm 3 32 3 2mm 1 8 ADV Note F Tungsten Type Note G GRN GRN TYPE Current selected value Colour WHTE GREY TURQ GOLD TIG STARTING PARAMETERS NOTE F Polarity EP EN EP POL Current sele...

Страница 21: ...ixed the minimum allowable current Table 10 Tungsten diameter Min AMP 3 2 mm 20 2 4 mm 10 1 6 mm 7 1 mm 2 For AC welding advanced users is present the possibility to modify the AC starting parameters...

Страница 22: ...step 1 Hot Start SOFT 30 0 75 step 1 HSTR Current selected value CRISP 50 50 200 step 1 Stick Polarity DC DC or DC STPL Current selected value ARC FORCE and HOT START With those two parameters user c...

Страница 23: ...FF OFF UPDN Current selected value type AMPS MEM MAX amparage OFF 51 199 OFF AMPS Current selected value A Cooler option AUTO AUTO COOL Current selected value type ON Control firmware revision N A N A...

Страница 24: ...in amperage the UP DOWN with remote device will work as described above MEM MODE By pressing torch buttons user will be allowed to change over settings stored in memory locations from 1 to 9 The featu...

Страница 25: ...ncoln Electric Maintenance or repairs performed by unauthorized service centers or personnel will null and void the manufacturer s warranty The frequency of the maintenance operations may vary in acco...

Страница 26: ...ing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Commun...

Страница 27: ...M W000382719 2 PROTIGIIIS 30RL C5B S 5M W000382720 2 PROTIGIIIS 30RL C5B S 8M W000382721 2 PROTIGIIIS 40RL C5B S 5M W000382722 2 PROTIGIIIS 40RL C5B S 8M W000382723 2 PROTIGIIIS 10W C5B S 5M W00038272...

Отзывы: