![Lincoln Electric ACTIVE8 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/lincoln-electric/active8/active8_operators-manual_1918831022.webp)
B-5
OPERATION
B-5
ACTIV8™
Trigger Interlock
Trigger Interlock operation provides for operator
comfort when making long welds. When the gun
trigger is first pulled, the welding power source
energizes the output and the wire feeder feeds
wire for welding. The gun trigger is then released
while the weld is made. To stop welding, the gun
triggerispulledagain,andwhenitisreleasedthe
weldingpowersourceoutputturnsoffandthewire
feederstopsfeedingwire.
If the arc goes out while welding with
trigger interlock operation, the elec-
trode output from the welding power
source remains energized and the wire
feeder will continue to feed wire until
the gun trigger is again pulled and
then released.
------------------------------------------------------------------------
4. CV/CC SWITCH
TheCV/CCswitchsetsthewirefeedspeedcon-
trolmethodforthewirefeeder.
PlacetherockerswitchintheUPpositionforCC
operationorintheDOWNpositionforCVopera-
tion.
IntheCCposition,the
wirefeedspeedvaries
duringwelding.Thearc
lengthismaintainedby
changingthewirefeed
speed.
IntheCVposition,the
wirefeedspeedremains
constantduringwelding.
Asteadyarcvoltageis
regulatedbythepowersourcebyadjustingthearc
current.
5. SPOOL RETAINER*
6. SPOOL BRAKE*
7. GUN BUSHING, THUMB SCREW AND
SOCKET HEAD CAP SCREW*
8. DRIVE ROLLS AND WIRE GUIDES*
*
(See
“Installation Section”
forfunctions.)
CAUTION
REAR CONTROLS
(See Figure B.3)
ITEM DESCRIPTION
1
ShieldingGasInletwithgasfilter
2
ElectrodeLead
FIGURE B.3
1
2