Cooling fan thermostat(s) 

Check the cooling fan thermostat. (Thermostat closes 
at 49

°

C and opens at 38

°

C). With the cooling fan 

thermostat preheated, check for continuity. If switch is 

open, replace. 

Fuse, 3 A., cooling fan 

Check, replace if necessary. 

Fuse holder 

Check, replace if necessary. 

Cooling fan(s) 

Supply voltage should now be at these motors. If 

voltage is present, check motor for opens, shorts or 

grounds. WITH POWER OFF: Check for locked rotor. 

Fan switch 

Check to see that the fan switch is on. 

Oven will not heat 

Main oven fan 

Check if main oven fan is operating. If not, refer to 

“Oven fan will not run”. 

NOTE: These ovens utilize 2 complete /Temperature control systems. Each system will Follow the same 

troubleshooting sequence. 

Oven control relay 

Check for line voltage to the relay coil. If no voltage is 

present, trace wiring back to the control box hi-limit 

thermostat(s). If voltage is present, check to insure 

contacts are closing. Replace relay as needed. 

Thermostat, oven cavity hi-limit 

Terminals are normally closed. If open, reset and test 

oven for proper operation. If thermostat will not hold 

for maximum oven temperature, and oven is not 

exceeding maximum temperature dial setting, check 

for proper location of capillary bulb in its spring holder 

If above checks OK, replace hi-limit. 

Contactor, hi-limit 

Check for line voltage to the contactor coil. If no 

voltage is present, trace wiring back to the oven cavity 

hi-limit thermostat(s). If voltage is present, check to 

insure contacts are closing. Replace contactor as 

needed. 

Fuse, heater, 50A. 

Check, replace if necessary. 

Fuseholder

 

Check, replace if necessary.

 

Control transformer 

Check for supply voltage to the primary of the control 

transformer. If no voltage is present, trace wiring back 

to the oven control relay. If primary voltage is present, 

check for 24VAC at the transformer secondary. If 

there is primary voltage, but no secondary voltage, 

replace control transformer. 

 

Oven control 

Check for 24VAC supply to control. If no voltage is 

present, trace wiring back to control transformer. If 

24VAC is present, check for a read-out on the control 

display. If there is 24VAC supplied, but there is no 

read-out on the control display, replace the oven 

control. 

If there is a read-out on the control, set the control to 

maximum temperature (see installation operations 

manual for temperature adjustment). With the control 

set at maximum temperature, check for line voltage at 

the heat relay (mercury contactor). If there is voltage 

at the heat relay, proceed to “Heat relay” for next 

check. If there is no voltage at the heat relay, trace 

wiring back to the oven control. If there is no voltage 

output at the oven control, check the read-out on the 

control. If the control reads “LP FAIL” or “RP FAIL”, 

this indicates that the thermocouple has failed or has 

become disconnected from the control. “LP FAIL” 

indicates a problem with the left thermocouple probe, 

and “RP FAIL” indicates a problem with the right 

thermocouple probe.  

Содержание 1621-000-EA

Страница 1: ...1621 000 EA 1628 000 A 1629 000 A WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790...

Страница 2: ...the control transformer and the conveyor motor TEMPERATURE CONTROL Closing the oven power switch supplies line voltage through the 10 amp fuse through the oven power relay to the primary of the contro...

Страница 3: ...Low Profile 1600 Series Adv Dig Electric S M Int l 3 SCHEMATIC MODEL 1621 000 EA 1628 000 A 1629 000 A...

Страница 4: ...the contact of the relay If no voltage is present trace wiring back to power filter If voltage is present at the relay coil check to insure the contacts are closing Replace relay as needed Hi limit t...

Страница 5: ...oil If no voltage is present trace wiring back to the oven cavity hi limit thermostat s If voltage is present check to insure contacts are closing Replace contactor as needed Fuse heater 50A Check rep...

Страница 6: ...he temperature regulation valve replace the oven control If there is voltage output to the heat relay proceed Oven air pressure switch Check for supply voltage at the air pressure switch if no voltage...

Страница 7: ...ply to the primary of the control transformer If no voltage is present trace wiring back to the oven power relay If voltage is present check for 24VAC at the transformer secondary If there is primary...

Страница 8: ...effect sensor Measure frequency across the yellow and white wires at the motor connector Frequency readings should be approx 20 525 Hz If these readings are not achieved replace the conveyor motor If...

Страница 9: ...nel top and front cover D Disconnect wiring from motor and mark for reassembly E Remove sprocket from motor shaft F Remove 4 screws and remove conveyor motor and mounting bracket G Remove mounting bra...

Страница 10: ...control box cover C Remove 2 wires from capacitor note wire number and location WARNING Capacitor has a stored charge discharge before handling or testing D Cut 2 tyraps securing capacitor to base and...

Страница 11: ...hroud 3 Make sure all connectors are properly seated and making good contact 4 When reinstalling gas manifold across back of oven check all fittings for leaks L Check system operation allow 30 minute...

Страница 12: ...Operating Instructions Manual C Remove conveyor belting from conveyor Remove drive sprocket from drive shaft D Move drive shaft or idle shaft toward end of conveyor and shaft with bearings will now sl...

Страница 13: ...d below the Sub Level program can be entered by pressing the two right buttons only 5 Set bake time and oven temperature Set Point Menu A Press and hold the 2 LH buttons to enter Set Point program Onc...

Страница 14: ...S N 35950 below 370663 Baffle air return U L S N 35951 above U 370166 Baffle air return U R L L S N 35950 below 370662 Baffle air return U R S N 35951 above V 370168 Finger housing T 1 T 3 B 2 B 4 S...

Страница 15: ...Low Profile 1600 Series Adv Dig Electric S M Int l 15 GENERAL VIEW...

Страница 16: ...40V K 7004970 Mounting Plate Top L 370251 Top Assembly RH M 7002976 Capacitor Bracket N 369192 Capacitor O 370485 Contactor Mercury 3P P 369368 Thermostat oven cavity hi limit R 357107 Fuse Holder S 3...

Страница 17: ...Low Profile 1600 Series Adv Dig Electric S M Int l 17 CONTROL BOX RIGHT VIEW...

Страница 18: ...Top 240V F 7004970 Mounting Plate Top G 369767 Firebar Element Bottom 220V 369792 Firebar Element Bottom 230V 369769 Firebar Element Bottom 240V H 7004973 Mounting Plate Bottom I 7006234 Control Box F...

Страница 19: ...Low Profile 1600 Series Adv Dig Electric S M Int l 19 CONTROL BOX LEFT VIEW...

Страница 20: ...PART DESCRIPTION A 369547 Wire form thermostat bulb B 369725 Fan clockwise rotation C 369776 Fan shroud D 369777 Stand off E 369778 Rear wall assy F 369761 Motor mount G 369759 Motor main fan 220 240...

Страница 21: ...Low Profile 1600 Series Adv Dig Electric S M Int l 21 OVEN BACK VIEW...

Страница 22: ...14 Roll conveyor notched C 2114003 nut hex D 369812 Conveyor idler shaft E 369160 Conveyor pan stop F 369641 Bracket idle bearing G 369220 Bearing idle H 369005 Connecting link 32 inch wide belt I 369...

Страница 23: ...Low Profile 1600 Series Adv Dig Electric S M Int l 23 CONVEYOR VIEW...

Страница 24: ...Low Profile 1600 Series Adv Dig Electric S M Int l 24...

Отзывы: