C-9
OPERATION
ARCLINK
This weld mode is intended to unlock basic non-synergic, synergic and
pulse modes intended for use with a compatible ArcLink wire feeders.
All of the Flextec™ 500 P user interface controls are disabled in this
mode and controlling the power source is accomplished from the wire
feeder user interface.
Hot Start
– Not used for this welding process
Arc Control
– Not used for this welding process
Weld Terminals On/Remote
• Not used for this welding process
• Not used for this welding process
Amperage LCD Display
– This display will display three dashed lines
when the machine is in the idle state. This indicates that amperage is
not settable in this weld mode. While output is enabled, the actual
welding amperage will be displayed. After welding, the meter holds
the actual amperage value for 5 seconds. Output adjustment while in
the "hold" period results in the "prior to operation" characteristics
stated above. The displays blink indicating that the machine is in the
"Hold" period.
Voltage LCD Display
– This display will display three dashed lines
when the machine is in the idle state. After welding, the meter holds
the actual voltage value for 5 seconds. Output adjustment while in the
"hold" period results in the "prior to operation" characteristics stated
above. The displays blink indicating that the machine is in the "Hold"
period.
Output Control Local/Remote
– Not used for this welding process
Output Control Dial
• Not used for this welding process
• Not used for this welding process
FLEXTEC™ 500 P
Содержание 12246
Страница 8: ...8 CHANGES AFTER INITIAL RELEASE FLEXTEC 500 P CHANGES AFTER INITIAL RELEASE...
Страница 12: ...12 NOTES FLEXTEC 500 P...
Страница 49: ...Flextec 500P 12607...
Страница 50: ...ii THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 55: ...P 1068 C jpg Case Front Assembly Flextec 500P 12607 5 Printed 09 29 2016 at 13 26 01 Produced by Enigma...
Страница 58: ...P 1068 D jpg Divider Panel Assembly 8 Flextec 500P 12607 Printed 09 29 2016 at 13 26 01 Produced by Enigma...
Страница 61: ...P 1068 E jpg Base Center Assembly Flextec 500P 12607 11 Printed 09 29 2016 at 13 26 01 Produced by Enigma...
Страница 63: ...P 1068 F jpg Case Back Assembly Flextec 500P 12607 13 Printed 09 29 2016 at 13 26 01 Produced by Enigma...
Страница 65: ...P 1068 G jpg Wraparound Assembly Flextec 500P 12607 15 Printed 09 29 2016 at 13 26 01 Produced by Enigma...