background image

IS212 ECN3592 

CONTENTS

 

 
 

 

FOREWORD 

 

 
 

1.

 

INSTALLATION INSTRUCTIONS 

6-7

 

 

1.1.

 

Ventilation 

 

1.2.

 

Installation Position 

 

1.3.

 

Installation Commissioning 

 

1.4.

 

Gas Supply and Connection 

 

1.5.

 

Pressure Setting 

 

1.6.

 

Heat Input 

 
 

2.

 

OPERATING INSTRUCTIONS 

8   

 

2.1.

 

Lighting of Appliance 

 

2.2.

 

Shut Down of Appliance 

 

 

2.3.

 

Preparation for Use 

 

 

2.4.

 

Care of Griddle Plates 

 

 
 

3.

 

SERVICING 

9-10 

 

3.1.

 

General Routine Servicing 

 

3.2.

 

Component Replacement 

 

3.3.

 

Spares List 

 
 

4.

 

TROUBLESHOOTING 

11 

 
 

5.

 

SERVICE INFORMATION 

12 

 

5.1.

 

Contact Information 

 

5.2.

 

Authorised service agents 

 

 

5.3.

 

Conditions of Guarantee 

Содержание Silverlink 600 GS4

Страница 1: ...IS212 ECN3592 Silverlink 600 Gas Griddles GS4 and GS7 User Installation and Servicing Instructions...

Страница 2: ...It is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation Failure to comply...

Страница 3: ...Pressure 25 mbar Injector size 0 88 mm Stamp code 100 Gas Rate 0 39 kg h 1 Low rate setting 0 11 kg h 1 1 litre min GS7 Units Dimensions 415 x 600 x 600 Weight 55kg Inlet connection BSP Natural Gas G...

Страница 4: ...essure Setting 1 6 Heat Input 2 OPERATING INSTRUCTIONS 8 2 1 Lighting of Appliance 2 2 Shut Down of Appliance 2 3 Preparation for Use 2 4 Care of Griddle Plates 3 SERVICING 9 10 3 1 General Routine Se...

Страница 5: ...ioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation Failure to comply will invalidate the warranty Whilst in operation parts of...

Страница 6: ...uld be a minimum clearance of 750mm between the top of the appliance and any overlying shelf or ceiling Where the unit is to be free standing any partitions walls or kitchen furniture in close proximi...

Страница 7: ...sure the supply pressure is set to 37mbar and the burner pressure is set to 25mbar Pressure measurement is via the test nipple at the end of the manifold rail Note To obtain the above burner pressures...

Страница 8: ...SE 2 3 1 Clean the surface of the griddle with hot soapy water Dry thoroughly and lightly coat in cooking oil 2 3 2 Ensure that the fat drawer is correctly positioned 2 3 3 Light the unit as described...

Страница 9: ...MPONENT REPLACEMENT Note When removing the control knob care must be taken not to lose the spring clip 3 2 1 Thermocouple Remove the fat drawer control knobs and fascia panel Remove the rear panel Sli...

Страница 10: ...the Lincat reference number followed by a brief description VA11 Multi function valve TC34 Thermocouple BU87 Griddle burner JE35 GS7 N Burner injector natural gas stamp code 160 JE141 GS7 P Burner inj...

Страница 11: ...eck gas supply check injector for blockages Check thermocouple connections tighten connections Check thermocouple voltage minimum 5mv replace thermocouple Check thermocouple location Distance from bur...

Страница 12: ...oes not cover Accidental breakage or damage Operational misuse wear and tear from normal usage incorrect adjustment or neglect Incorrect installation maintenance modification or unauthorised service w...

Отзывы: