Error codes
There are numerous error codes identifying issues within the induction system. These
are primarily of use when reporting a fault to Lincat’s Service Department; however
some errors can be cleared by turning the control to the ‘Off’ position, unplugging the
appliance and then switching back on again.
A reduction in performance during cooking may be attributed to a blocked or restricted
air filter, a confined location with insufficient airflow or a failed cooling fan.
Error codes are shown on the display
This list shows the standard error codes. As standard general TC (thermocouple)
errors are “Er xx“ and cooking element specific errors E/x are displayed.
Error code
Description
Possible cause of error
Remedy
Er 03 and
continuous
tone or
continuous sensor activation; TC
turn off after 10 sec
Water or cookware on the
glass over the touch
control sensors
Clean the control surface,
remove objects on the
sensors
Er 20
Flash memory – TC error
µC- defective
Replace TC
Er 22
Button evaluation defective, UI
shuts off after 3.5-7.5 sec
Short or open circuit in the
area of the button sensor
Replace TC
Er 31
Incorrect configuration data or
deviation between generator and
TC
New configuration of the
induction generator
required
New configuration (Service
menu)
Er 36
NTC value defective on TC; UI
turns off
Short or open circuit of
NTC
Replace TC
Er 47
Communication error between
TC and induction
No or erroneous LIN
communication! (Slave
does not answer to
request of master)
Connection cable not
correctly plugged in or
defective.
U 400
Continuous tone
Power supply on inlet to high
Incorrect connection of the
cooktop
Correct power supply
connection
E / 2
Excess temperature of the
induction element
Overload of cooktop or
empty boiled cookware
Let system cool down.
E / A
Error on the power board
Component failure
Replace power board
E / 6
Error on power board or supply
element
No power supply of the
power element or error on
power board
1. check wiring
2. check filter board
3. replace power board
E / 8
Incorrect fan speed
Error on fan left or right
Air exhaust blocked,
e.g. by paper
Replace Defective fan
E / 9
Defective temperature sensor on
inductor
Replace inductor
Replace power board