INSTALLATION AND COMMISSIONING
This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L1
Black wire Live L2
Grey wire Live L3
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of at least 60
o
C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
If the supply cable is replaced, the live conductors must pass through the ferrite ring
for EMC compliance. Do not pass the neutral or earth wire through the ferrite ring.