INSTALLATION
SITING
The appliance must be installed in accordance with the appropriate regulations listed prior.
The appliance should be installed on a level surface ensuring the unit is stable, firmly located and
positioned to minimise the possibility of accidental touching.
A clear space of at least 100mm must be left to the rear of the appliance to allow for servicing with a
clear space of 600mm to the front to allow for safe operation. A minimum space of 100mm must be
left between any side of the unit and any combustible surface or walls.
Any partitions, walls or kitchen furniture in close proximity must be of non-combustible
materials and not be closer than 100mm from the sides and rear of the flue.
ELECTRICAL SUPPLY AND CONNECTION
Connection of the electrical supply cable is made at the rear of the unit. Remove the protective cover
and fit a suitable cable into the strain relief and then to the inlet terminal block. The unit is supplied
for connection to a three-phase supply. Refer to schematic on page11.
HOTPLATES
Hotplates are controlled by six position rotary switches, ‘6’ is the hottest. Off is indicated by a filled
circle as shown in the control panel illustration on page 5.
.