IS150 ECN 2038
Please read the following carefully before commencing work on this equipment
WARNING AND PRECAUTIONS
This appliance must be installed by a competent installation engineer, in accordance with the
installation instructions and all relevant local and national standards including the following:
•
Health and Safety at Work Acts
•
IEE regulations
•
BS Codes of Practice
•
Local and National Building Regulations
•
Fire Precautions Act 1971
•
EN 60335-1 1994 and EN 60335-2-48 1997
It is mandatory that all appliances are installed, commissioned and serviced by a qualified and
competent person as defined by the regulations in force in the country of installation.
Failure to do so may invalidate the warranty.
!!!!
If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
SECTION 1 - TECHNICAL DATA
Model number
LT4X
LT6X
Overall height (mm)
245
245
Width (mm) inc handles
390
480
Depth (mm) (excluding controls)
220
220
Weight (Kg)
6
7.5
Electricity supply requirements
Single phase 9.4 Amps
Single phase 12.5Amps
Electricity supply connection
Single phase 13A plug
Single phase 13A plug
Power rating @240V (kW)
2.2
3
Check list of enclosures
Please ensure that the following items are included with this piece of equipment
Model
LT4X
LT6X
Tick
Crumb tray (fitted in the toaster base)
1
1
User instructions
1
1
Guarantee card
1
1