OPERATING INSTRUCTIONS 

INSTALLATION 

 

Ensure that the unit is installed on a sound, level work surface, which is heat resistant e.g. stainless steel 

or formica. Inform your personnel that the external surfaces and base will become hot.

 

 

 

 

 For safety regulations, the plug must always be accessible

 

 CONNECTING TO THE ELECTRICITY SUPPLY 

 

Ensure  that the voltage  of  your electricity supply corresponds to the serial plate  details.  The product is 

supplied with a 13 amp plug.  To replace the plug, follow these instructions: 

 

 

green and yellow wire to 'E' or (Earth) 

 

blue wire to 'N' (Neutral) 

 

brown wire to 'L' (Live) 

 

 

 

 

 

 

 

 

 

 

1

3

2

 

 

Fig 1.  - Model LPG 

 

 

 

Control knob 

Green neon 

Amber neon

 

Connect the unit to the electricity supply.  The green neon will then light up. Turn the control knob to set the desired 

temperature. When the cooking surfaces have heated up to the set temperature, the amber neon will extinguish. 

To turn the unit off, turn the control knob to ‘0’ 

 

NOTE:

 That /S units have a 20 minute mechanical timer 

 

Safety (High Limit) Thermostat 

 

This unit is fitted with two thermostats.  One controls the temperature of the cooking surfaces; the other prevents the 

temperature from reaching a dangerous level if there is a fault with the unit or power supply.  

 

If the green neon lights up but the element does not heat up,  the safety thermostat may need to be re-set.  

To re-set the thermostat, push the button located at the rear of the unit. (Fig. 2) 

Note:  The re-set button cannot be activated until the unit has cooled sufficiently 