OPERATING INSTRUCTIONS
INSTALLATION
Ensure that the unit is installed on a sound, level work surface, which is heat resistant e.g. stainless steel
or formica. Inform your personnel that the external surfaces and base will become hot.
For safety regulations, the plug must always be accessible
.
CONNECTING TO THE ELECTRICITY SUPPLY
Ensure that the voltage of your electricity supply corresponds to the serial plate details. The product is
supplied with a 13 amp plug. To replace the plug, follow these instructions:
•
green and yellow wire to 'E' or (Earth)
•
blue wire to 'N' (Neutral)
•
brown wire to 'L' (Live)
1
3
2
Fig 1. - Model LPG
1
Control knob
2
Green neon
3
Amber neon
Connect the unit to the electricity supply. The green neon will then light up. Turn the control knob to set the desired
temperature. When the cooking surfaces have heated up to the set temperature, the amber neon will extinguish.
To turn the unit off, turn the control knob to ‘0’
NOTE:
That /S units have a 20 minute mechanical timer
Safety (High Limit) Thermostat
This unit is fitted with two thermostats. One controls the temperature of the cooking surfaces; the other prevents the
temperature from reaching a dangerous level if there is a fault with the unit or power supply.
If the green neon lights up but the element does not heat up, the safety thermostat may need to be re-set.
To re-set the thermostat, push the button located at the rear of the unit. (Fig. 2)
Note: The re-set button cannot be activated until the unit has cooled sufficiently