SECURITY DISTANCES
•
From NOT combustible object :
−
A > 500 mm
B > 200 mm
C > 200 mm D > 1500 mm
•
From combustible object and from principal wall in rein forced concrete :
−
A > 1000 mm
B > 400 mm
C > 400 mm D > 1500 mm
•
The minimal distance between the stove and every flammable object around it is 1.5
meter.
1.4
Connection
•
Before connection check technical data reported in the technical plate ( Chap. 4 ) and
control that it correspond to the ones required in the order.
•
All heating biomass equipment especially wood stove has to evacuate the combustion
products in a flue built in conformity with normative in force.
•
The following instructions describes „ informations for a good installation „ and it refers
to a normative in force but it are not to be consider exhaustive for installations laws.
COLLAR EXHAUST FUMES ASSEMBLY
•
Take off the collar from the fire door.
•
Place the collar on the top of the stove ( see the
picture ) assemble it with the screws.
•
Place the Fume Ring inside the collar.
•
Position the ceramic head and the sheet metal
frame as shown in the image.
NB. If there are difficulties in pulling the chimney,
try removing the Fume Ring.
Metal Frame
Ceramic Head
Collar
Exhaust
Fumes
Fume Ring