IT
IT
IT
IT----GB
GB
GB
GB----FR
FR
FR
FR----ES
ES
ES
ES mod. 702A-G -702A-GL 2019
2019
2019
2019 EN13240
23/76
Valid for all Model - Measure from
external side of the equipment
SECURITY DISTANCES
•
From NOT combustible object :
−
A > 400 mm
B > 250 mm
C > 250 mm
D>1000 mm
•
From combustible object and from principal wall in reinforced concrete :
−
A > 800 mm
B > 500 mm
C > 500 mm
D> 1500 mm
•
The minimal distance among the top of the appliance and any flammable object over it is
1.5 meter.
1.4
Connection
•
Before connecting the appliance, check the technical data reported in the technical plate
( Chap. 4 ) and control that it correspond to the ones required in the order.
•
All heating biomass equipments, especially wood burning appliances, have to evacuate
the combustion products in a flue, built in conformity with the normatives in force.
•
The following instructions describe „ informations for a good installation „ and refer to a
normative in force but they are not to be consider exhaustive for installations laws.
COLLAR EXHAUST FUMES ASSEMBLY
•
The appliance is supplied ready for connection of
the collar Vertical exhaust fumes.
•
However, you can connect the collar exhaust
fumes also in the back part of the stove
Mounting with Vertical Exhaust
:
•
Place the collar over the plate and with the date
supplied screws screw the collar on the plate
Exhaust fumes
collar
Radiant
plate
Plate
frame