LINC milton roy L471 Series Скачать руководство пользователя страница 19

Product Description:

The LV-471 is used as a high or 
low level control to sound 
alarms, operate control equip-
ment or perform a variety of 
desired electrical functions. 
These controls will operate in 
any specific gravity of 0.7 or 
higher. The standard unit has a 
3" O.D. spherical float and is 
rated at 250 psi. The standard 
float arm is 4" long. Various 
floats and float arm lengths are 
available to fit your application. 
These controls are available 
with a normally closed or nor-
mally open switch arrangement.  
This unit is installed through a 
1-1/2" NPT fitting and the float 
is attached with a cotter key 
after the body is screwed into 
place. Various flanged models 
are also available to meet your 
specifications.

I N S T R U C T I O N   M A N U A L

L

I

N

C

-

L

V

4

7

1 :

V

E

R

T

I

C

A

L

Figure 9, LINC LV471-04, Vertical Level Switch

-N

(SUPPLIED WITH 
1/2” REDUCER 
BUSHING)

, ) . #  - ) ,4 / .  2 / 9  s      ) 6 9 , ! . $  2 / ! $  s  ) 6 9 , ! . $  0!         s  5 3 !  s  4 % ,                s  & ! 8             

Page 18

Содержание L471 Series

Страница 1: ...ION MANUAL E L E C T R I C L E V E L C O N T R O L S s 3 s 6 s 3 2 3 Recognized as a world class leader in Electric Pneumatic level control switches flow indicators chemical metering pumps and allied...

Страница 2: ...Page 1 To Order Call 800 455 LINC Or FAX your order anytime to 215 293 0498 For the Nearest Authorized Representative By Telephone 800 455 LINC for the US Canada 215 293 0465 or 215 441 0800 for Inter...

Страница 3: ...L471 02 03 Level Switch Parts List 9 Figure 3 L471 01 04 Level Switch 10 L471 01 04 Level Switch Parts List 10 Figure 4 L471 39 79 Level Switch 11 L471 39 79 Level Switch Parts List 11 Figure 5 L471...

Страница 4: ...fering with electrical circuity Available with Stainless Steel and Polypropylene displacer options for various process pressures Benefits Easy toRepair Easy to Field Test NoLeaks Lower Operating Costs...

Страница 5: ...metically sealed plug in 120VAC DPDT 10 Amp 05 This number means special specify your requirements i e 3 flanged 150 RF Option Number Factory will assign an option number based on specified requiremen...

Страница 6: ...The small float per mits an economical installation in locations where other controls would be cost prohibitive With the optional relay mounted in an explosion proof case the control of larger electri...

Страница 7: ...pull on the switch assembly Caution Do not exceed switch ratings LINC L471 LINC L471SC SPST 100 VA AC with 3 AMP inrush capability maximum 250 volts Breakdown voltage is 300 volts Electrical ratings a...

Страница 8: ...at to the float arm To remove the float arm drive out the pivot pin using a 1 8 punch When installing the float arm make certain that the threaded offset of the float arm is against the thick wall of...

Страница 9: ...acer 316 ss 2 4 20853 24883 Float Arm Assembly 316 ss 1 5 30313 30715 Body 316 ss 1 20495 20495 Switch Cartridge 304 ss 1 7 10087 10087 Grommet Nitrile 1 8 10012 10012 Name Plate 316 ss 1 9 10324 1032...

Страница 10: ...03 Item Part Part Description Material Qty 1 20149 20136 Float Polypropylene 1 2 20120 20120 Pin 316 ss 1 3 20121 20121 Spacer 316 ss 2 4 20853 21671 Float Arm Assembly 316 ss 1 5 30313 30313 Body 316...

Страница 11: ...Parts List Model L471 01 04 N Item Part Description Material Qty 1 10245 Float 316 ss 1 2 20120 Pin 316 ss 1 3 20121 Spacer 316 ss 2 4 20853 Float Arm Assembly 316 ss 1 5 30313 Body 316 ss 1 20495 Swi...

Страница 12: ...rive Screw 18 8 ss 2 3 10087 10087 Grommet Nitrile 1 4 20119 20119 Conduit Adapter 316 ss 1 20495 20495 Switch Cartridge Sealed 1 6 31079 31079 Body 316 ss 1 7 23540 23540 Float Magnet Arm 316 ss 1 8...

Страница 13: ...9 23604 23604 Spacer 316 ss 1 10 23503 23503 Displacer Polypropylene 1 11 11571 Pin 316 ss 1 12 24887 24887 Ring Weldment 316 ss 1 13 10996 10996 O Ring Fluorocarbon 1 14 22271 22271 Packing Gland 316...

Страница 14: ...in the enclosure using accepted electrical practices Connect the other side of the source black wire terminal 2 3 The load may now be wired to terminals 1 3 4 and 8 5 and 6 4 Secure the enclosure cove...

Страница 15: ...EAD 3CREW Plated 1 4 12001 Terminal ring Insulated 1 5 20948 Mounting Plate Aluminum 1 6 10472 Relay Base Plastic 1 10688 Relay 110 VAC 1 25747 Relay Enclosure with Lid Plated 1 2ECOMMENDED SPARE OME...

Страница 16: ...4 20334 20334 Pin 316 ss 1 5 20121 20121 Spacer 316 ss 2 6 10211 10211 Cap Screw Plated 6 20495 20495 Switch Cartridge Sealed 1 8 30282 30282 Body 316 ss 1 9 20119 20119 Conduit Adapter 316 ss 1 10 1...

Страница 17: ...7 10087 Grommet Nitrile 1 11 30258 30258 Ring Flange Steel 2 12 10013 See below Name Plate 316 ss 1 13 10324 See below Drive Screw not shown 18 8 ss 2 24836 See below Switch Cartridge SPDT 400 F Optio...

Страница 18: ...c level control LINC _______ ________ _________ Ordering Chart Series LV471 Verticalelectriclevelcontrol L971 Horizontalelectriclevelcontrol BodyStyle 03 Standard unit 1 1 2 NPT normally open LV471 on...

Страница 19: ...ious floats and float arm lengths are available to fit your application These controls are available with a normally closed or nor mally open switch arrangement This unit is installed through a 1 1 2...

Страница 20: ...46 Float Arm Assembly 316 ss 1 The LINC LV471 04 Normally Closed Parts List Model LV471 04 04 N Normally Closed Item Part Description Material Qty 1 21593 Relay Assembly 110 VAC see relays 1 2 20119 C...

Страница 21: ...standard float is a solid high density polypropyl ene material and will operate in specific gravities of 0 6 or high er Due to the length of the float these controls must have 3 of vertical clearance...

Страница 22: ...et Nitrile 1 6 12972 Name Plate 316 ss 1 7 13060 Drive Screw 18 8 ss 1 8 13061 Clamp 18 8 ss 1 2ECOMMENDED SPARE SUPPLIED WITH 1 2 REDUCER BUSHING Model L971 01 04 Series Item Part Description Materia...

Страница 23: ...NOTES...

Страница 24: ...OPYRIGHT ILTON 2OY IT...

Отзывы: