4. INSTALLATION
Cut out the work surface according to the sizes
shown in the drawing. For the purpose of
installation and use, a minimum of 5 cm space
shall be preserved around the hole. Be sure the
thickness of the work surface is at least 30mm.
Please select heat resistant and insulated work
surface material (wood and similar fibrous or
hygroscopic material shall not be used as work
surface material unless impregnated) to avoid the
electrical shock and larger deformation caused
by the heat radiation from the hotplate. As shown.
The safety distance between the sides of the
cooktop and the inner surfaces of the worktop
should be at least 3mm.
750
50
50
50
50
500
58
52
770
535
4.1 Selection of installation equipment
: The safety distance between the hotplate and the cupboard above the hotplate should be at least 60mm.
760mm
There are ventilation holes around outside of
the cooktop. YOU MUST ensure these holes are
not blocked by the worktop when you put the
cooktop into position.
Unit (mm)
760
50 min
20 min
Air intake
Air exit (5mm)
3.3 Touch control panel
LS30C2Z
LS60C3Z
LS30C2Z
LS60C3Z
Under any circumstances, make sure the Induction cooktop is well ventilated and the air inlet and outlet are