The appliance is only to be used with the power supply unit provided with the
appliance.
Furthermore take care about the connecting wires from the power supply to
the CBH Basic System, don’t damage this by overrun.
Assure free space for movement of application in both directions to avoid
blockade.
Safety issues
The builder of the equipment shall ensure that the use of the component
complies with relevant standards – like the Machine Directive. Care must be
taken to avoid squeezing of cables as it can cause movement of the system!
The SMPS001/002 must not be packed in heat insulating material, but must
be placed so that it can emit waste heat to the surroundings. There are no
ventilation holes to consider, the SMPS emits heat through its surface.
Only the power supply type SMPS001 or SMPS002, or similar suited products
meeting the requirements EN 60335-1, shall be used with the system (CBH
basic System).
Please observe that the actuators LA27 used for CBH Basic systems are with
signal end-stop switches and are not compatible with CBH Advanced systems
The SMPS006 is not compatible with the CBH Basic system. The system is only
released to 24V DC (SMPS006 = 29V DC)
It is possible only to use 1 power supply (SMPS001 or SMPS002) for 2 CBH
systems. Remember speed may decrease when running 2 systems at the same
time.