Page 15 of 26
Disposal of LINAK products
As LINAK customers often ask us how our products can be disposed of or scrapped, we have prepared this guidance that
enables a classification to different waste fractions for recycling or combustion.
Guidance
We recommend our products be disassembled as much as possible and divided into different waste groups for recycling or
combustion.
For example, waste can be sorted into metals, plastics, cable scrap, combustible material and recoverable resources.
Some of these main groups can be further divided into subgroups; e.g. metal can be divided into steel/aluminium/copper and
plastic can be divided into ABS/PA/PE/PP.
As an example, the table below breaks down the different components in LINAK products to various recycling groups:
Main groups of disposal
Product main groups
Metal
scrap
Cable
scrap
Electronics
scrap
Plastic recycling or
combustion
Comments
LA18 IC Standard Master
X
X
X
X
LA18 IC Standard Follower
X
X
X
X
SMPS001 / 002 / 006
X
X
Hand controls
X
X
X
LED Light Rail
X
X
X
Disposal of batteries
Details regarding safe disposal of used and leaking batteries:
Batteries should be disposed in accordance with appropriate federal, state and local regulations. LINAK recommends that
used or leaking batteries are disposed through local recycling system. Please do not throw used or leaking batteries in normal
household waste or in nature. This will cause damage to the enviroment.
How to deal with leaking batteries
Leaking batteries should be disposed as described above.
If leaking batteries are discovered in the product, the batteries must be removed at once to minimise damage to the product. If
leaking batteries are left in the product, it become defective.
It is recommended to use plastic gloves when handling leaking batteries. The contents of a leaking batteries can cause chemi-
cal burns and respiratory irritation.
If exposed to the contents of a leaking battery, please wash with soap and water. If irritation persists, please seek medical
attention. In case of eye contact, please flush eyes thoroughly with water for 15 minutes and seek medical attention.
Product
Components
Recycling group
Column/ Actuator :
Spindle and motor
Plastic housing
Cable
PC boards
Metal scrap
Plastic recycling or combustion
Cable scrap or combustion
Electronics scrap
Control Box :
PC boards
Plastic housing
Cable
Transformer
Electronics scrap
Plastic recycling or combustion
Cable scrap or combustion
Metal scrap
Handset/Control :
Plastic housing
Cable
PC boards
Plastic recycling or combustion
Cable scrap or combustion
Electronics scrap
By now, almost all our casted plastic parts are supplied with an interior code for plastic types and fibre contents, if any.
Содержание HOMELINE LA18 IC Standard Series
Страница 1: ...Page 1 of 26 LINAK COM HOMELINE Actuator LA18 IC Standard User manual...
Страница 18: ...Page 18 of 26 DRAWING APPENDIX LA18 IC Standard Master LA18 IC Standard Follower...
Страница 19: ...Page 19 of 26 LA18 IC Standard Master Click on back fixture LA18 IC Standard Follower Click on back fixture...
Страница 20: ...Page 20 of 26 SMPS001 SMPS002...
Страница 21: ...Page 21 of 26 SMPS006...
Страница 22: ...Page 22 of 26 13 5 34 100 2 9 1 3 HC05 Wireless HC10 Wireless...
Страница 24: ...Page 24 of 26 LED Light Rail HB10 Wireless...