Page 16 of 36
Mounting of the foot part
The DL5/DL6 bottom plate is supplied with four M6 and two M8 threaded holes.
1. Mount column bottom on desk feet using four M6 or two M8 screws with the following specifications:
Quality: Min. grade 8.8
Length: Min. 10 mm (plus foot thickness);
Max. 16 mm (plus foot thickness) for M6
Max. 14 mm (plus foot thickness) for M8
2. Fasten screws thoroughly (torque: max. 10 Nm).
The holes in the foot must be sufficiently larger than ø6/ø8 to ensure space for the screw heads to be screwed fully into the
foot.
Column bottom mounted on desk foot (left: M6; right: M8)
Bottom plate