Page 17 of 35
Mounting crossbar
We have experienced a few cases where customers have designed a desk with a crossbar with a hidden column bracket,
where the bracket has been pulled out when tightening the crossbar. To eliminate this failure, please follow the guidelines
below when constructing a desk.
If the crossbar connection is made with a design where the bracket is hidden inside the crossbar profile, make sure
that you do not pull out the bracket in the column when tightening the screws for the assembly.
The maximum torque for tightening the 2 x M8 screws in the bracket is 15 Nm.
To avoid damage of the lifting unit there must be at least 1 mm space between the ends of the two M8 screws for the
mounting bracket and the lifting unit surface. Screws that are too long will come into contact with the inner parts. This will
result in an irregular operation or even damage the lifting unit.
These guidelines also apply to a bench solution.
Requirement: Min. 1 mm space between ends of screws and lifting unit surface