10
Feedback types
Current Feedback:
Voltage Feedback:
The position of the actuator can be correlated to current output. The available current range is 4-20 mA.
The user can select values in the whole range but the highest resolution is achieved with the widest current
range. The minimum setting is the IN EOS or virtuel limit in position and the maximum is the OUT EOS or
virtuel limit out.
The position of the actuator can be correlated to a voltage output as well. The available voltage range is
0-10 V. The user can select any set of values in that range but the highest resolution is achieved with the
widest voltage range. The minimum setting is the IN EOS or virtuel limit position and the maximum is the
OUT EOS or virtual limit out.