0190045 Page 2 of 4
4 LED light
bars on battery
Figure 2
Figure 3
There are four light bars indicating the battery capacity:
Capacity between 0% and 5%
Capacity between 5% and 25%
Capacity between 25% and 50%
Capacity between 50% and 75%
Capacity between 75% and 100%
No lights
LED 1 lights
LED 1, and LED 2 lights
LED 1, LED 2, and LED 3 lights
LED 1, LED 2, LED 3, and LED 4 lights
Battery protection
• The battery limits the discharge current to approximately 10A by
disconnecting the power.
• The battery can go into a protected mode. Then a reset is made only
after disconnecting the cable and in some cases charging the battery.
• If the battery stops working please try the following:
- Disconnect the cable from the battery.
- Press the button on the battery for minimum 10 seconds.
- Charge the battery
- Connect the battery again.
• In overload situations, the LED light bars will still turn on when
activated. If the capacity is below approximately 25% it is not possible
to identify if the battery has switched off due to overload or low
capacity. Rule of thumb is that the battery must be charged if no LED
light bars can be turned on.
• To check/identify the problem, charge the battery. If the battery still
switches off it is due to an overload situation.
Charging Battery
BA001 Battery
AC Power
Cord
CBD6S Control Box
DC Cord
• When the capacity is below 25%, the audio alarm sounds once when
activating the battery.
• The battery turns off to protect itself when the capacity is
approximately 5%. Below the 5% capacity, the audio alarm sounds
when activating the battery. No LED light bars can be activated.
• When charging, the LED light bars indicate the current charge capacity
• When the charging is complete the LED light bars will turn off
• Charging will not start if the capacity is above 75%
AC Wall Outlet
To Charge:
1. Leave the battery plugged into the control box with the DC cord.
2. Plug the control box into a wall outlet using the AC power cord.
3. When the AC power cord is connected, and charging has started,
the battery will beep twice. Charge time is approximately 5 hours at
room temperature (around 20° C).
Button
The LED light bar indicators turn on when you press the small black
button below the light bars. The light will only be on for a few seconds.
Switching between AC supply and battery use
Please observe that when you change from standard mains supply to the
BA001 (battery) the first operation may be at a lower speed/performance.
This only refers to the very first operation after the disconnection of the
mains supply.
The technical reason for this is that the charge left in the control box is still
high, so the control box assumes the mains supply is still connected and
regulates according to mains supply characteristics.
After about ½ hour, or after trying to operate without power, the charge is
low enough to be detected as battery operation mode. The same goes if