Parameter Table   

Code 

Function 

Range 

Unit 

Indication 

Default 

T10  Temperature control working mode 

0 ~ 2 

 

0: R1 up/down limit control 
1: External SSR, up/down limit control 
2: External SSR, PID control 

T11  Temperature set point 

0.0 ~ 100.0 

/

   

37.8 

T12  Temperature hysteresis for R1 (T10 = 0) 

0.0 ~ 20.0 

/

  Relative to T11, absolute value: T11 - T12 

0.2 

T13  Temperature hysteresis for SSR (T10 = 1) 

0.0 ~ 20.0 

/

 

Relative to T11, absolute value: T11 - T13 

0.3 

T14  Min stop time for temperature load (R1) 

0 ~ 999 

sec   

T20  Temperature calibration 

-9.9 ~ +9.9 

/

   

0.0 

T21  High temp. alarm relative point 

0.

0 ~ 65.0/dis

 

/

 

dis: disable warning. 

Absolute point = T11 + T21 

dis 

T22  Low temp. alarm relative point 

0.

0 ~ 65.0/dis

 

/

 

dis: disable warning. 

Absolute point = T11 - T22 

dis 

T25  High temp. protection relative point 

0.

0 ~ 65.0/dis

 

/

 

dis: disable warning. 

Absolute point = T11 + T25

 

Ref.: U20 = 1/2/3, U30 = 

1/2/3

, U40 = 

1/2/3 

0.2 

T26  Hysteresis for T25 

0.0 ~ 65.0 

/

 

Absolute point = T11+T25

-T26 

Ref.: U20 = 1/2/3, U30 = 

1/2/3

, U40 = 

1/2/3 

0.1 

T30  Proportion of SSR PID 

0.1 ~ 5000 

Power/

 

Kp for PID 

39.3 

T31  Integration of SSR PID 

0 ~ 5000 

sec  Ti for PID. If Ti = 0, shut integration. 

15.7 

T32  Differential of SSR PID 

0 ~ 5000 

sec  Td for PID. If Td =0, shut differential. 

40.5 

H10  Dehumidify / humidify mode 

0 / 1 

 

0: dehumidify, 1: humidify 

H20  Humidity set point 

0 ~ 99 

%RH   

50 

H21  Humidity hysteresis 

0 ~ 50 

%RH  Relative to H20, absolute value: H20 - H21 

H22  Humidity calibration 

-9.9 ~ +9.9 

%RH   

0.0 

H23  Minimum stop time for humidity load (R3) 

0 ~ 30 

min   

H24  High humidity warning relative point 

~ 80/dis

 

%RH 

dis: disable warning. 

Absolute point = H20 + H24 

dis 

H25  Low humidity warning relative point 

~ 80/dis

 

%RH 

dis: disable warning. 

Absolute point = H20 - H25 

dis 

H26  High humidity protection relative point 

0 ~ 80/dis 

%RH 

dis: disable warning. 

Absolute point = H20 + H26

 

Ref.: U20 = 1/2/3, U30 = 

1/2/3

, U40 = 

1/2/3

 

H27  Hysteresis for H26 

~ 80 

%RH 

Absolute point = H20-H26

-H27 

Ref.: U20 = 1/2/3, U30 = 

1/2/3

, U40 = 

1/2/3

 

U10  Left turn (R6) time unit 

1 ~ 2 

 

1: minute, 2: hour 

U11  Left turn (R6) time of the timer 

1 ~ 999 

 

 

120 

U12  Right turn (R7) time unit 

1 ~ 2 

 

1: minute, 2: hour 

U13  Right turn (R7) time of the timer 

1 ~ 999 

 

 

120 

U14  Turning times 

0 ~ 999 

 

0: unlimited turning times 

U16  Turning motor working mode 

0 / 1 

 

0: Either R6 or R7 will be energized.   
    Need position  switches,  position  arrival  shuts off 

the power supply to motor 

1: Only energized during turning moment (U17).   

Manual egg turning support 

U17  Motor being energized time for every turning 

0 ~ 999 

sec  Effective only when U16 = 1 

30 

U18  Hatching days 

0 ~ 99 

day  0: disabled hatching days counting 

0

 

U20  Output R5 (air exhaustion) control mode 

0 ~ 3 

 

0: Air exhaust 
1: Air e humi./temp. 

high

 limit protection 

2: Air e temperature 

high

 limit protection 

3: Air e humidity 

high

 limit protection 

U21  Time unit for air exhaust period (R5) 

0 ~ 2 

 

0: second, 1: minute, 2: hour 

U22  Air exhaust period (R5) 

1 ~ 999 

 

 

30 

U23  Time unit for air exhausting time (R5) 

0 ~ 2 

 

0: second, 1: minute, 2: hour 

U24  Air exhausting time (R5) 

1 ~ 999 

 

 

30 

U30  Output R4 (Lamp or protection) control mode 

0 ~ 

3

 

 

0: illumination control 

1

: temperature and humidity 

high

 limit protection 

2

: Temperature 

high

 limit protection 

3

: humidity 

high

 limit protection 

U34  Output R4 delay time for automatic shutdown 

1 ~ 999 

Min  Only effective when U30 = 0 

U40  Output R8 (alarm or protection) control mode 

0 ~ 

3

 

 

0 = alarm output 

1 = temperature and humidity 

High 

limit protection 

2 = temperature 

high

 limit protection 

3 = humidity 

high

 limit protection

 

U50

 

Door switch mode

 

0 / 1

 

 

0: Normal close, 1: Normal open

 

0

 

U65

 

Buzzing warning option

 

0 / 1

 

 

0: disable warning, 1: enable warning

 

1

 

U90  Password 

000 ~ 999 

 

000 = no password 

U93  PID self auto tune power rate 

10 ~ 100 

Percent of heater’s full power rate

 

50 

Содержание ZL-7903A

Страница 1: ...ta 6 Output R5 Control 6 R5 as periodical air exhaustion U20 0 6 R5 as periodical air exhaustion temperature and humidity high limit protection U20 1 6 R5 as periodical air exhaust temperature high limit protection U20 2 6 R5 as periodical air exhaust humidity high limit protection U20 3 6 Output R4 Control 6 R4 as illumination control U30 0 6 R4 as Temperature and humidity high limit protection U...

Страница 2: ... 8 Alarm output 9 Auto restart function 10 Temperature humidity over limitwarning and protection 11 Temperature humidity sensor faultwarning and protection Specification Power supply 100 240VAC 50 or 60Hz Output and input Output Input Heater control relay 250VAC 7 5A 1 0A Resistive load R1 Temperature sensor NTC 5K 3470 Ventilation control relay 7 5A 1 0A R2 Humidity sensor ZL SHr05J Humidity cont...

Страница 3: ...perature higher than up limit Warning No warning tLo Temperature lower than down limit Warning No warning HHi Humidity higher than up limit Warning No warning HLo Humidity lower than down limit Warning No warning UnL Restore to default parameters Restoring to defaultparameters dr Door is opened Door open Buzzing Every key press there will be a beep When there is error of sensors high low limit tem...

Страница 4: ... dis RH dis disable warning Absolutepoint H20 H26 Ref U20 1 2 3 U30 1 2 3 U40 1 2 3 5 H27 Hysteresis forH26 0 80 RH Absolute point H20 H26 H27 Ref U20 1 2 3 U30 1 2 3 U40 1 2 3 2 U10 Left turn R6 time unit 1 2 1 minute 2 hour 1 U11 Left turn R6 time of the timer 1 999 120 U12 Right turn R7 time unit 1 2 1 minute 2 hour 1 U13 Right turn R7 time of the timer 1 999 120 U14 Turning times 0 999 0 unlim...

Страница 5: ...U93 50 the power rate is 50 of full power rate External SSR PID control T10 2 See paragraph Apendix PID control High temperature protection Protection reaction could be R5 R4 or R8 depends on settings When room temperature T11 T25 start protecting When room temperature T11 T25 T26 stop protecting Humidity Control R3 Humidify control H10 1 If room humidity H20 H21 and R3 has stopped for H23 R3 will...

Страница 6: ... Press to turn the lamp on off When the lamp is turned on it will be off after U34 automatically Under this setting When door is opened R4 will be energized for U34 time When door is closed R4 will be de energized R4 as Temperature and humidity high limit protection U30 1 If room temp T11 T25 or room humidity H20 H26 R4 energized If room temp T11 T25 T26 and room humidity H20 H26 H27 stop protecti...

Страница 7: ...flashing If the counter value reaches 99 stop counting Keeping depressed for 3 seconds will reset the accumulated times of egg turning and incubation day counter Restore to Factory Default Settings When the controller is online keep and depressed simultaneously for 3 seconds The display shows UnL Then press twice the controller will restore the parameters to factory defaultsettings Fahrenheit Cels...

Страница 8: ... power rate If the overshootor over falling to SP 0 2 auto tuning is not able to get the PID parameters correctly The following will also make auto tuning failure or getwrong PID parameters The PV vibration amplitudes differ too much The PV vibration periods differ too much The PV changes not smoothly there are temperature interference like opened door at some moment b Try to get best parameters I...

Отзывы: