3 – Mechanical installation
WARNING
Installation and maintenance operations must be carried out by qualified
personnel only, with power supply disconnected and mechanical parts
absolutely in stop.
3.1 Overall dimensions (Figure 1)
(values are expressed in mm)
Figure 1
L = 195 mm / 7.677” ÷ 650 mm / 25.59” (see the order code of the MTAG
profile)
3.2 Mounting instructions
Install and use the product in conformance with the protection level it has been
designed to. Protect the unit against knocks, frictions and solvents and avoid
temperatures over the allowed range.
Make sure the unit is mounted where hard or sharp objects (e.g. turnings, chips
or filings) do not come into contact with the magnetic tape and the bottom of
the sensor head. If these conditions cannot be avoided provide adequate
cleaning measures (as for instance brushes, scrapers, jets of compressed air, etc.)
in order to prevent the sensor and the magnetic tape from jamming.
The profile of the magnetic tape must be inserted in the track at the bottom of
the sensor enclosure; the shape of the track is univocal in order to prevent
mounting errors.
Two mounting options are allowed:
1. you can fasten the profile of the magnetic tape to a fixed support and
move the sensor;
MAN SMAG GA E 1.3.odt
3 – Mechanical installation