![Lika RD4 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/lika/rd4/rd4_user-manual_1916075063.webp)
RD4 CANopen®
Operating parameters
3005-00 Current value [mA]
[Integer16, ro]
This object shows the value of the current absorbed by the motor (rated
current). Parameter is expressed in mA (milliamperes).
3006-00 Temperature value
[Integer16, ro]
This object shows the value of the internal temperature of the device as sensed
by a probe. Value is expressed in °C (Celsius degrees). The minimum detectable
temperature is -20°C.
3100-00 Control word
[Unsigned32, rw]
This object contains the commands to be sent in real time to the Slave in order
to manage it.
parameter is used to edit PDO messages
received by the Slave (see further details in the section “7.6 PDO messages” on
page 37).
3101-00 Status word
[Unsigned16, ro]
This object shows information about the device state.
object is contained in the PDO messages sent by the Slave (see further details in
the section “7.6 PDO messages” on page 37).
3102-00 Demanded position value
[Integer32, ro]
This object shows the value of the theoretical position calculated by the device
while moving. This value is used by PI controller to control the motor.
3103-00 Current position value
[Integer32, ro]
This object shows the value of the current position.
object is contained in the PDO messages sent by the Slave (see further
details in the section “7.6 PDO messages” page 37).
MAN RD4 CB E 1.5
Programming parameters
63 of 72
Содержание RD4
Страница 1: ...User s guide RD4 Position measurement control ...
Страница 71: ...This page intentionally left blank ...