![Lika RD4 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/lika/rd4/rd4_user-manual_1916075056.webp)
RD4 CANopen®
Device profile objects
3108-00 Acceleration
[Unsigned32, rw]
This object defines the acceleration value that has to be used by the device.
Parameter is expressed in pulses per second
2
[PPS
2
].
Default = 1000
3109-00 Deceleration
[Unsigned32, rw]
This object defines the deceleration value that has to be used by the device.
Parameter is expressed in pulses per second
2
[PPS
2
].
Default = 1000
310C-00 Max following error
[Unsigned32, rw]
This object defines the maximum allowable difference between the real position
and the theoretical position of the device. If the device detects a value higher
than the one set in this object, the alarm
unit stops. Parameter is expressed in pulses.
Default = 1024
310D-00 Position window
[Unsigned16, rw]
This object defines the tolerance window for the
value. When the axis is within the tolerance window limits for the time set in
the object
, then the state is signalled through
status bit. Parameter is expressed in pulses.
Default = 0
310E-00 Position window time
[Unsigned16, rw]
It represents the time for which the axis has to be within the tolerance window
limits set in the object
status bit. Parameter is expressed in milliseconds.
Default = 100
MAN RD4 CB E 1.5
Programming parameters
56 of 72