EM58 • HS58 • HM58 POWERLINK
1F9B-00 NMT_MultiplCycleAssign_AU8
[Unsigned8, rw]
These objects assign the nodes to the particular POWERLINK cycles of the
multiplexed
cycle
period
defined
by
NMT_CycleTiming_REC.MultiplCycleCnt_U8
. The value has to be equal in all
nodes of the segment. This sub-Index contains the number of entries.
Default = 254 (min. = 1, max. = 254)
1F9B-01 NMT_MultiplCycleAssign_AU8.CycleNo
[Unsigned8, rw]
Each sub-Index in the array corresponds to the node with the Node ID equal to
the sub-Index. The sub-Index value is valid only if there is a multiplexed node
assigned to the Node ID by index
NMT_NodeAssignment_AU32
[sub-Index]
bits 0, 1 and 9.
This object defines the POWERLINK cycle index in the multiplexed cycle, when
the respective node are accessed. If the value is “0”, the node is accessed
continuously.
Default = 0 (min. = 0, max. = 255)
1F9E NMT_ResetCmd_U8
[Unsigned8, rw]
This is used to initiate the reset of a node.
Setting
NMTResetNode
,
NMTResetConfiguration
,
NMTResetCommunication
or
NMTSwReset
will
trigger the node internal generation of a respective NMT command to itself.
NMTInvalidService
by the
node when the reset has been completed.
On read access,
always shows
NMTInvalidService
.
If applied in
NMT_CS_EPL_MODE
may violate the NMT rules and stimulate DLL and NMT Guarding errors.
Default = 255 (min. = 0, max. = 255)