LD220
6.13 Command menu
The
Command
menu allows to configure the operation of the inputs “10 - Ctrl.
In 1”, “11 - Ctrl. In 2” and “12 - Ctrl. In 3”.
For complete information on the control inputs features, please refer to the “4.5
Control inputs” section on page 24.
Input 1 action
This parameter sets the function of the input “10 - Ctrl. In 1”.
0
NO
No function
1
RESET/SET VALUE
The currently acquired position value is
transferred -after bit suppression and
possibly performed encoder zero
offset- to the
see on page 55.
(d) (s)
2
FREEZE
It freezes all display values.
NOTE
Analogue output and switching
outputs still react to changes!
(s)
3
KEY LOCK
It disables the touch screen.
(s)
4
LOCK RELEASE
It releases the lock in all outputs / relay. (d)
5
RESET MIN/MAX
It resets the minimum / maximum
values.
(d) (s)
6
SERIAL PRINT
It allows serial data to be transmitted,
see the
page 73.
(d)
7
TEACH PRESEL. 1
The current display value is stored as
Preselection 1 (see the
parameter on page 60). The reference
source is the one selected in
see on page 61.
(d)
8
TEACH PRESEL. 2
The current display value is stored as
Preselection 2 (see the
parameter on page 60). The reference
source is the one selected in
see on page 65.
(d)
9
TEACH PRESEL. 3
The current display value is stored as
Preselection 3 (see the
parameter on page 60). The reference
source is the one selected in
see on page 67.
(d)
10 TEACH PRESEL. 4
The current display value is stored as
Preselection 4 (see the
parameter on page 60). The reference
source is the one selected in
(d)
MAN LD220 E 1.4.odt
6 – Menus and parameters
76 of 100
Содержание Posicontrol LD220 Series
Страница 99: ...This page intentionally left blank...