LD220
4 - Electrical connections
WARNING
Power supply must be turned off before performing any electrical connection!
The terminal block screws must be tightened using a slotted screwdriver having
a 2 mm wide blade.
4.1 DC power supply
DC power supply technical specifications (-P8- order code)
Input voltage:
Protection circuit:
Power consumption:
Fuse protection:
18Vdc ... 30Vdc
reverse polarity protection
approx. 150 mA (unloaded)
external fuse T 0.5 A
The unit accepts DC supply from 18 to 30 V through terminal blocks 1 and 2.
The power consumption depends on the level of the supply voltage (approx. 150
mA) and the additional current required by the Auxiliary Voltage output (3 –
GND + 4 – Aux. Out, see the “4.3 Auxiliary voltage output” section on page 19).
All GND terminal blocks are internally connected.
NOTE
For AC power supply (-PM- order code) see the following section.