7 - BiSS C-mode interface
Order code: standard SMA1-SCx-5-…
SMA1 is a Slave device and complies with the “BiSS C-mode interface” and the
“Standard encoder profile”.
For detailed information not listed in this manual please refer to the official
BiSS website (www.biss-interface.com).
The device is designed to operate in a point-to-point configuration and has to
be installed in a “single Master - single Slave” network.
WARNING
Never connect the sensor in a “single Master - Multi Slave” network.
CLOCK MA and DATA SLO signal levels comply with the “RS-422 EIA standard”.
7.1 XML file
The product is supplied with an XML file
idbiss4C69.xml
).
Install the XML file in your BiSS Master device.
7.2 Communication
The BiSS C-mode protocol uses two types of data transmission protocols:
Single Cycle Data (SCD):
this is the primary data transmission protocol. It
is used to transmit the process data from the Slave device to the Master
device. See the “7.3 Single Cycle Data” section on page 32.
Control Data (CD):
transmission of a single bit following the SCD data. It is
used to read data from or write data to the registers of the Slave. See “7.4
Control Data CD” section on page 33.