SMA1
Configuration
[49, rw]
Bit
Function
Bit = 0
Bit = 1
0
BiSS
SSI
1
Preset
Offset
2
Enable preset / offset Enable
Disable
3
Not used
4
Not used
5
Gray
Binary
6
*
Standard
Inverted
7
Not used
*
: it affects the absolute position information, not the sine/cosine signals
Select BiSS / SSI
It sets whether the output data is transmitted using the BiSS B-mode protocol
(0) or the SSI protocol (1).
Default = 0 (BiSS B-mode)
Set preset / offset
This parameter is available only if the parameter
is set to
ENABLE. It allows to activate either the preset function (
PRESET) or the offset function (
Offset value has to be set in the
register. After having enabled
the preset / offset functions (
= ENABLE), this item allows
to activate either the preset function or the offset function. The value set in the
register will have a different meaning depending on the value
of this parameter whether it is set to PRESET (0) or OFFSET (1). In the first case
(
preset value; while in the second case (
register is used to set the offset value. To activate the preset / offset
Save and activate Preset / Offset
register (set “02” in the register 48).
For any information on the preset and the offset functions refer to the
register on page 27.
Default = 0 (Preset)
Enable preset / offset
It enables / disables the preset / offset functions. After having enabled the use of
the functions you have to choose whether to activate the preset or the offset in
the
parameter. Then to active a new value, set it next to the
Save and activate Preset / Offset
command (set “02” in the register 48).
Default = 0 (enable)
MAN SMA1 E 2.9.odt
6 - BiSS B-mode interface
25 of 48