SMA1
4 - Electrical connections
WARNING
Electrical connection has to be carried out by qualified personnel only, with
power supply disconnected and mechanical parts compulsorily in stop.
WARNING
If wires of unused signals come in contact, irreparable damage could be caused
to the device. Please insulate them singularly.
Connections
Function
T12 cable
M12 12-pin
0Vdc
White_Green
1
+Vdc
1
Brown_Green
2
Clock IN + / MA +
Violet
3
Clock IN - / MA -
Yellow
4
Data OUT + / SLO +
Grey
5
Data OUT - / SLO -
Pink
6
not connected
White
7
not connected
Blue
8
A (cos+)
Green
9
/A (cos-)
Brown
10
B (sin+)
Red
11
/B (sin-)
Black
12
Shielding
Shield
Case
1 See the order code for the power supply voltage level.
EXAMPLE
SMA1-SC
2
-... +Vdc = +10Vdc +30Vdc
→
SMA1-SB
1
-... +Vdc = +5Vdc
→
±5%
4.1 T12 cable specifications
Model
: LIKA T12 cable
Wires
: 4 x 0.25 mm
2
+ 4 x 2 x 0.14 mm
2
twisted pairs
Shield
: tinned copper braid
External diameter : Ø 6.1 mm ± 0.10 mm
Conductor resistance
: <90
/km (0.25 mm
2
); <148
/km (0.14 mm
2
)
Minimum bending radius
: Ø x 7.5
MAN SMA1 E 2.9.odt
4 - Electrical connections
14 of 48