background image

MC150

User manual

MC150

Description

This manual describes the MC150 display series. The 
purpose   of   this   device   is   to     display   linear   or 
angular displacements on industrial machines and 
automation systems. The device can be connected 
to  standard  Push-Pull  or  Line   Driver  incremental 
encoders or magnetic sensors.  

Chapters

1

Safety summary

2

Identification

3

Installation

4

Mounting recommendations

5

Electrical connections

6

Functions

7

Set up

8

RS232 interface

9

Dimensional drawing and cut-out

1 - Safety summary

For the electrical connections, we recommend to 
closely   follow   these   electrical   instructions.   In 
particular, according to the 89/336/EEC norm on 
electromagnetic   compatibility,   following 
precautions must be taken:

Measurement   system   (sensor)   should   be 
installed as close as possible to the display.

Always   use   shielded   and   twisted   cables   if 
possible.

Avoid   running   the   sensor   cable   near   high 
voltage power cables (e.g. drive cables).

Install EMC filters  on  sensor  power  supply  if 
needed.

Avoid   mounting   sensor   near   capacitive   or 
inductive noise sources such as relays, motors, 
and switching power supplies.

Static discharge can damage internal sensitive 
electronic   components.   Before   handling   and 
installing,   discharge   electrical 
charge from your body and tools 
which may come in touch with 
the device.

Connect   according   to   the   chapter   5:   “Electrical 
connections”.

2 - Identification

The   device   can   be   identified   by   the   label's   data 
(ordering code, serial number).  This information is 
listed   in   the   delivery   document.   For   technical 
features of the product to make reference at the 
technical catalogue.

3 - Installation

Install the device according to the protection level 
provided.   Protect   the   system   against   knocks, 
friction,   solvents   and   respect   the   environmental 
characteristics of the product.

4 - Mounting recommendations

Push the display into the cut-out (approx. 90 x 66 
mm

2

) without panel clips.

Install   panel   clips   on   the   display's   housing   and 
screw until fixed.

MAN MC150 I_E 1.7

9

www.lika.it

www.lika.biz

Содержание MC150 series

Страница 1: ...voltage power cables e g drive cables Install EMC filters on sensor power supply if needed Avoid mounting sensor near capacitive or inductive noise sources such as relays motors and switching power s...

Страница 2: ...Pin 4 N max 100 mA Pin 5 P E 5 2 CON2 connections sensor input Pin Function 1 GND 2 24Vdc J1 left power supply 24Vdc 12Vdc J1 left power supply 115Vac 230Vac 5Vdc J1 right any power supply 3 A 4 A see...

Страница 3: ...ss to setup menus Push F key to enter setup push to select Func 1 or Func 2 push E to scroll parameters push F to exit setup Admissible value range for each parameter is listed as follows min value ma...

Страница 4: ...estore default value see chapter Default parameter 6 2 1 P07 Function of the push buttons 0 6 The function of the and the E buttons in operating mode can be selected 0 no functions 1 E will set actual...

Страница 5: ...6 Output configuration 0 1 0 static output 1 with output dwell time see P17 and P18 P17 Output 1 dwell time 0 2 50 Enter output dwell time between 0 and 2 50 seconds P16 must be 1 Default value 0 P18...

Страница 6: ...ion in sec P62 must be 1 Default value 1 00 P99 Actual value for RS232 99999 999999 This parameter shows the actual value for serial transmission via RS232 Interface if parameter P62 0 NOTE In order t...

Страница 7: ...smission is correct slave replies with ACK in any other cases with NAK MC150 PC ACK or NAK All parameters sent to the slave are stored in a data buffer Parameters have to be activated by the activate...

Страница 8: ...the following data string will be transmitted MC150 printer AD1 AD2 DATA LF CR xx xx xx 0A Hex 0D Hex The MC150 is sending its serial address followed by the actual value and Line Feed LF and Carriage...

Отзывы: