5.3 Teach operation
NOTE
The time-out function remains disabled during all Teach operations.
Key
Function
ENTER
key will terminate or abort any Teach operation in
progress
SET
function is fully similar to normal set-up operation
CMD
key will save the display value in the register and
change over to the next interpolation point
For further details on the Teach procedure see section “8.2 Manual input or
„teaching“ of the interpolation points” on page 32.
5.4 Setting all registers to “Default“ values
At any time you can return all settings to the factory default values.
WARNING
This action will reset all parameters to factory default values and your own
settings will be lost. You will have to repeat your individual set-up procedure.
Factory default values are shown in the subsequent parameter tables (see
section “Parameters list” on page 34).
To reset the unit to default values:
•
switch power off;
•
press the
ENTER
key on the front;
•
keep
ENTER
down while you power up again.