IF55 ROT CANopen®
= 01h (= Gray code)
= 00h (= 32-bit “LSB Right Aligned” protocol)
= 20h (= 32 dec)
2200-04 Physical Singleturn Resolution [bits]
cpr)
2200-05 Physical Multiturn Resolution [bits]
= 0Eh (= 14 bits = 16,384 rev.)
6502-00 Number of distinguishable
objects are automatically set accordingly and used to arrange the
position information
Total Physical Resolution
Number of distinguishable revolutions
If you want to use the physical resolution:
Bit 2
= 0
If you need a custom resolution:
Bit 2
= 1
Now set the resolution you need for your application next to the
Programmable pulse per revolution
objects
5.1 Quick reference
After setting the SSI encoder parameters and then using the default settings
provided by the manufacturer, you can read immediately the position value.
Follow the instructions below to:
read the physical resolution of the device: physical singleturn resolution
; number of physical revolutions
Number of distinguishable revolutions
set the desired cycle time:
≠
0
set the
Operational
mode;
read the current position (in a cyclic mode and/or in a synchronous mode).
The default Baud rate and Node-ID are:
Baud rate = 500 Kbit/s
Node-ID = 1
MAN IF55 ROT CB E 1.2.odt
5 - Getting started
38 of 88